Chapter 2
Setting Up the ETERNUS DX/AF
2.1
Common Settings
[For a Cluster Configured With Veritas InfoScale]
If all the following conditions are met, instead of selecting the host response, configure new settings ac-
cording to the table below. All other parameters should be left on their default values.
•
The firmware version is V10L50 or later
Thin Provisioning is used
•
OS
Solaris
Linux
HP-UX
AIX
[For IBM SVC]
If all the following conditions are met, instead of selecting the host response, configure new settings ac-
cording to the table below. Follow the values of "SVC" for all the parameters that are not described.
The ETERNUS DX8700 S3/DX8900 S3 is used
•
•
The number of LUNs exceeds 256
Parameter
LUN Expand Mode
(Peripheral Device Addressing)
[For VMware]
If all the following conditions are met, instead of selecting the host response, configure new settings ac-
cording to the table below. All other parameters should be left on their default values.
The firmware version is V10L61 or earlier
•
VMware ESXi 6.0 Update 2 or later, or VMware ESXi 6.5 or later is used
•
•
VMware vSphere Virtual Volumes (VVOL) is used
Parameter
Sense Data Conversion
Parameter
Reservation Conflict Response
(Write Exclusive)
LUN Addressing
Peripheral Device Type
(Flat Space Addressing)
NACA
Reservation Conflict Response
(Write Exclusive)
LUN Addressing
NACA
Reservation Conflict Response
(Write Exclusive)
11
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection-
Copyright 2017 FUJITSU LIMITED
Setting value
GOOD
FLAT
Controller Device (0Ch)
Enable
GOOD
FLAT
Enable
GOOD
Setting value
Enable
Setting value
5/25/00 g 5/20/00
P3AM-7962-15ENZ0