Fujitsu ETERNUS8000 1100 Manual - Página 11

Procurar online ou descarregar pdf Manual para Armazenamento Fujitsu ETERNUS8000 1100. Fujitsu ETERNUS8000 1100 28 páginas. Disk storage systems (fibre channel) for oracle solaris
Também para Fujitsu ETERNUS8000 1100: Manual (21 páginas), Manual de ligação do servidor (25 páginas), Manual de ligação do servidor (32 páginas), Manual de ligação (19 páginas)

Fujitsu ETERNUS8000 1100 Manual
Chapter 3 Notes
>

3.2 Server Startup and Power Supply Control Notes

Example LAN switch connection configuration
A separate LAN segment is used for each
Server/Storage grouping. (*2)
Here, LAN ports 1, 2 and 10 comprise VLAN1,
while LAN ports 3 and 11 comprise VLAN2.
*1:
In this system configuration, multipaths provide redundant connections between the servers and
storage system. LAN switches #1 and #2 provide physical separation of the network paths.
*2:
A separate LAN segment is provided in the LAN switch (using the switch VLAN function) for each
grouping of business servers and disk storage systems (equivalent to the FC zones).
3.2
Server Startup and Power Supply Control Notes
Before turning the server on, check that the ETERNUS Disk storage systems and LAN switches
are all "Ready". If the server is turned on and they are not "Ready", the server will not be able to
recognize the ETERNUS Disk storage systems.
Also, when the ETERNUS Disk storage system power supply is being controlled by a con-
nected server, make sure that the ETERNUS Disk storage system does not shut down before
the connected servers. Similarly, the LAN switches must also be turned off after the connected
servers have been shut down.
If turned off, data writes from the running server cannot be saved to the ETERNUS Disk storage
systems, and already saved data may also be affected.
P3AM-4182-03ENZ0
Server Connection Guide (iSCSI) for Oracle Solaris
LAN switch
[Business LAN]
LAN
LAN
card
card
#1
#1
Business server A
Business server B
LAN
LAN
LAN
card
card
card
#2
#3
#2
1
2
3
LAN switch #1
LAN switches should not
[iSCSI LAN]
be inter-connected (*1)
10
11
12
LUN1
LUN2
LUN3
Management
ETERNUS Disk storage system
LAN
card
#1
Business server C
LAN
LAN
LAN
card
card
card
#3
#2
#3
1
2
3
LAN switch #2
[iSCSI LAN]
10
11
12
Management LAN
LAN switch
LAN port
[Management LAN]
The iSCSI LAN and management
LAN segments are kept separate
in the iSCSI LAN switches, helping
maintain the security of each.
11
Business LAN
Similarly to FC-SAN, a
dedicated LAN is used for
iSCSI, not the business LAN.
iSCSI LAN
Copyright 2010 FUJITSU LIMITED