AEG OSC6T185ES Manual do utilizador - Página 18
Procurar online ou descarregar pdf Manual do utilizador para Frigorífico AEG OSC6T185ES. AEG OSC6T185ES 24 páginas.
1. Open the drawer.
2. Pull out the exhausted air filter.
3. Insert the new air filter in the slot.
4. Close the drawer.
To get the best performance the drawer
should be placed properly and the CleanAir
filter should be changed once every year.
8. TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
8.1 What to do if...
Problem
The appliance does not operate.
The appliance is noisy.
Acoustic or visual alarm is on.
The compressor operates continual‐
ly.
18
ENGLISH
The air filter is a consumable accessory
and as such is not covered by the
guarantee.
New active air filters can be purchased
from your local dealer. To change the air
filter repeat the procedure.
7.6 Period of non-operation
When the appliance is not in use for long
period, take the following precautions:
1. Disconnect the appliance from electricity
2. Remove all food.
3. Clean the appliance and all accessories.
4. Leave the doors open to prevent
Possible cause
The appliance is switched off.
The mains plug is not connected to
the mains socket correctly.
There is no voltage in the mains
socket.
The appliance is not supported
properly.
The cabinet has been recently
switched on.
The temperature in the appliance is
too high.
The door is left open.
Temperature is set incorrectly.
Many food products were put in at
the same time.
supply.
unpleasant smells.
Solution
Switch on the appliance.
Connect the mains plug to the
mains socket correctly.
Connect a different electrical appli‐
ance to the mains socket. Contact a
qualified electrician.
Check if the appliance stands sta‐
ble.
Refer to "High temperature alarm"
or "Door open alarm".
Refer to "High temperature alarm"
or "Door open alarm".
Close the door.
Refer to "Control panel" chapter.
Wait a few hours and then check the