2N APS Mini Manual do utilizador e de serviço - Página 4

Procurar online ou descarregar pdf Manual do utilizador e de serviço para Unidade de controlo 2N APS Mini. 2N APS Mini 11 páginas. Standalone reader module, reader module with attendance keypad

Overview of module's features in various regimes of operation
Definition of access rights using programming cards
Signalization of reading a card and releasing the door lock
Acoustic signalization of alarm situations
Changing the parameters of regimes of operation and alarms
Definition of access rights from the PC
Visualization of the regime of the reading module, recording
events in an archive in the PC, viewing and working with events
Controlling the output of the reading module directly from the PC

Technical parameters

Dimensions
Power supply
Max. power input
ID technology
Max. number of access cards in the memory
inputs
Output for door lock
Alarm output
Protective contact (tamper)
Max. reading distance
Communication channel
Alternative data output
Signalization
Working temperature
Max. relative humidity
Supply cable length
Configurable operational parameters
Lock release duration
Acoustic signalization of lock releasing
Maximum duration of door opening
Duration of acoustic signalization of violation
Duration of acoustic signalization of door broken open
Duration of acoustic signalization of door open too long
nd
Function of the 2
input
Function
Parameter
autonomous
105 x 90 x 20 mm
10 ÷ 15 VDC
150 mA
EM Marin, 125kHz
748
2x logical, non-potential
1x relay switch contact 2 A / 24 V
Transistor output 5 V / 5 mA
Opto-electrical
Normally 8 cm with ISO cards
RS485 galvanic non-separated
WIEGAND (configurable)
2x LED + piezzo-buzzer
-25 ÷ +60°C
95%, without condensation
0,5 m
Possible values
÷
0
255 s
Yes / no
÷
0
255 s
÷
0
255 s
÷
0
255 s
÷
0
255 s
Leaving button /
contact handle
4
Regime of operation
offline
online
Default value
7 s
Yes
30 s
30 s
30 s
0 s
Leaving button