Indesit I5GG1/UK Manual de Instruções - Página 4

Procurar online ou descarregar pdf Manual de Instruções para Fogões Indesit I5GG1/UK. Indesit I5GG1/UK 16 páginas.
Também para Indesit I5GG1/UK: Manual de Instruções (16 páginas)

Indesit I5GG1/UK Manual de Instruções

Gas connection

T he cooker should be connected to the gas-supply
GB
by a Gas Safe registered installer. During installation
of this product it is essential to fit an approved gas
tap to isolate the supply from the appliance for the
convenience of any subsequent removal or servicing.
Connection of the appliance to the gas mains or liquid
gas must be carried out according to the prescribed
regulation in force, and only after it is ascertained that it
is adaptable to the type of gas to be used. If not, follow
the instructions indicated in the paragraph headed
"Adaptation to different gas types". On some models
the gas supply can be connected on the left or on the
right, as necessary; to change the connection, reverse
the position of the hose holder with that of the cap and
replace the gasket (supplied with the appliance). In the
case of connection to liquid gas, by tank, use pressure
regulators that conform to the regulation in force. The
HOT PARTS
"Caracteristics of the burners and nozzles". When
the cooker is installed between cabinets (recessed),
the gas connection must be effected by an approved
flexible hose with bayonet fitting (BS 669 Current
Edition). The gas inlet for the cookers is a threaded G
1/2 gas female fitting.
Connecting the gas supply
To make the connection, a flexible hose should be
used corresponding to the current gas regulations
which are:
• the hose must never be at any point in its lenght in
contact with the "hot" parts of the cooker;
• the hose must never be longer than 1,5 metre;
• the hose must not be subject to any tension or
torsional stress and it must not have any excessively
narrow curves or bottlenecks;
• the hose must be easy to inspect along its entire
length to check its condition;
• the hose must always be in good condition, never
attempt to repair.
! The installation must comply with gas safety
(installation and use) regulations 1984. In all cases for
the above, by low, a qualified, corgi approved engineer
must be called for installation.
* Only available in certain models
4
gas supply must be
connected to the left of
the appliance. Be sure
that the hose does not
pass through the rear of
the cooker touching hot
parts.
! Make sure the supply
pressure conforms
with the values shown
in the table entitled
Electrial connection
Power supply voltage and frequency: 230-240V a.c.
50/60 Hz.
! The supply cable must be positioned so that it never
reaches at any point a temperature 50°C higher than
the room temperature. The cable must be routed away
from the rear vents. Should you require it, you may
use a longer cable, however, you must ensure that the
cable supplied with the appliance is replaced by one
of the same specifications in accordance with current
standards and legislation.
Your appliance is supplied with a 13 amp fused
plug that can be plugged into a 13 amp socket for
immediate use. Before using the appliance please read
the instructions below.
WARNING - THIS APPLIANCE MUST BE EARTHED.
THE FOLLOWING OPERATIONS SHOULD BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN.
Replacing the fuse:
When replacing a faulty fuse, a 13 amp ASTA
approved fuse to BS 1362 should always be used, and
the fuse cover re-fitted. If the fuse cover is lost, the
plug must not be used until a replacement is obtained.
Replacement fuse covers:
If a replacement fuse cover is fitted, it must be of the
correct colour as indicated by the coloured marking
or the colour that is embossed in words on the base of
the plug. Replacements can be obtained directly from
your nearest Service Depot.
Removing the plug:
If your appliance has a non-rewireable moulded plug
and you should wish to remove it to add a cable
extension or to re-route the mains cable through
partitions, units etc., please ensure that either:
• the plug is replaced by a fused 13 amp re-wireable
plug bearing the BSI mark of approval.
or:
• the mains cable is wired directly into a 13 amp cable
outlet, controlled by a switch, (in compliance with
BS 5733) which is accessible without moving the
appliance.
! For appliances with a rating greater than 13 amp (eg:
electric hob, double ovens and freestanding electric
cookers etc.) the mains cable must be wired into a
cooker output point with a rating of 45 amp. In this
case the cable is not supplied.