Disposing of the appliance
When disposing of the appliance please remove the
plug by cutting the mains cable as close as
possible to the plug body and dispose of it as
described above.
Adapting the cooker to different types of
gas
In order to adapt the cooker to a different type of
gas with respect to the gas for which it was
produced (indicated on the label attached to the lid),
follow these steps:
a ) a ) replace the hose holder mounted on the appliance
a ) a )
a )
with that supplied in the bag of "cooker
accessories".
b )
b )
b )Replacing the burner nozzles on the hob:
b )
b )
• remove the grids and slide the burners from their
housings;
• unscrew the nozzles using
a 7 mm socket spanner, and
replace them with nozzles for
the new type of gas (see table
1 "Burner and nozzle
characteristics").
• replace all the components
by repeating the steps in
reverse order.
c ) c )
c ) c ) Minimum regulation of the hob burners:
c )
• turn the tap to minimum;
• remove the knob and
adjust the regulation screw,
which is positioned in or next
to the tap pin, until the flame
is small but steady.
! in the case of liquid gas, the
regulation screw must be
screwed in to the bottom.
• check that the flame does not turn off when you
turn the tap quickly from high to low.
d )
d )
d )
d )
d )Regulating the primary air of the burners:
The primary air of the burners requires no regulation.
Important
Important
Important
Important
Important
On completion of the operation, replace the old
rating sticker with one indicating the new type of gas
used. This sticker is available from our Service
Centres.
Note
Note
Note
Note
Note
Should the pressure of the gas used be different (or
vary) from the recommended pressure, it is
necessary to fit a suitable pressure regulator onto
the inlet pipe in compliance with current National
Regulations relative to "regulators for channelled
gas".
GB
5