Indesit KD6G25X Manual de Instruções - Página 18
Procurar online ou descarregar pdf Manual de Instruções para Fogões Indesit KD6G25X. Indesit KD6G25X 24 páginas. Free standing gas cooker
Também para Indesit KD6G25X: Manual de instruções de instalação e utilização (32 páginas), Manual de Instruções (24 páginas)
Installation
Prior to installation, ensure that the local distribution
GB
conditions (nature of the gas and gas pressure) and
the adjustment conditions are compatible. The
adjustment conditions for this appliance are stated
on the data badge which is fitted on the back panel.
This appliance is not designed to be connected to a
combustion products evacuation device. It must be
installed and connected in accordance with current
installation regulations. particular attention should be
given to the relevant requirements regarding
ventilation.
MODEL NUMBERS KD6G25X, KDP60G,
KD6G25M/W, KD6G25A
Category II2H3+ (GB)
These models are set to burn NATURAL GAS (G20)
at 20 mbar but can be converted for use on BUTANE
(G30) at 28-30mbar or PROPANE (G31) at 37mbar
with the use of the LPG conversion kit that can be
obtained free of charge, if you contact our Genuine
Parts and Accessories department (see Key
Contacts, back page).
GAS SAFETY (INSTALLATION & USE)
REGULATIONS
It is the law that all gas appliances are installed by
competent persons in accordance with the current
edition of the above regulations. It is in your interest
and that of safety to ensure compliance with the law.
In the UK, CORGI registered installers work to safe
standards of practice. The cooker must also be
installed in accordance with BS 6172. Failure to
install the cooker correctly could invalidate the
warranty liability claims and could lead to
prosecution.
Burner
Hotplate
Front Left
Hotplate
Rear Left and Rear Right
Hotplate
Front Right
Grill
Main Oven
Top Oven
18
LOCATION
The cooker may be located in a kitchen, kitchen/
diner or a bed-sitting room, but not in a room
containing a bath or shower. The cooker must not be
installed in a bed-sitting room of less than 20m
When adjusted for use on Butane (G30) or Propane
(G31), the cooker must not be installed in a room or
internal space below ground level, e.g. in a
basement.
PROVISION FOR VENTILATION
The room containing the cooker should have an air
supply in accordance with BS 5440: Part 2.
The room must have an opening window or
equivalent; some rooms may also require a
permanent vent. If the room has a volume between 5
and 10m
effective area unless it has a door which opens
directly to outside. If the room has a volume of less
than 5m
effective area. If there are other fuel burning
appliances in the same room, BS 5440: Part 2
should be consulted to determine air vent
requirements.
TECHNICAL DATA
Gas connection
Pressure test point
Gas rate adjustment
Aeration adjustment
Electrical connection
G20 at 20mbar
Heat Input
Injector
3.0 kW
116
2.0 kW
103
1.1 kW
79
2.8 kW
129
2.5 kW
115
1.9 kW
100
, it will require an air vent of 50cm
3
, it will require an air vent of 100cm
3
Rp ½ (½" BSP female)
Front left hotplate injector
None
None
Flexible cord fitted with a
3 pin 13 amp plug
230/240V a.c. 50Hz.
13A fuse.
G30 at 28-30mbar
G31 at 37mbar
Heat Input
3.0 kW (220g/h)
2.0 kW (145g/h)
1.0 kW (70g/h)
2.8 kW (200g/h)
2.3 kW (165g/h)
1.9 kW (135g/h)
.
3
2
2
Injector
86
70
50
85
71
66