AEG 3010 D Instruções de utilização e de instalação - Página 5
Procurar online ou descarregar pdf Instruções de utilização e de instalação para Campânula de ventilação AEG 3010 D. AEG 3010 D 17 páginas. Aeg cooktop user manual
Também para AEG 3010 D: Manual de operação e instalação (19 páginas)
Introduction
Extractor version
• The hood is supplied in the extractor version, but it can also be used
in the filter version by inserting an activated charcoal filter (special
accessory).
• To do this, use an original AEG activated charcoal filter (see Special
accessories).
• The air is discharged to the outside through a pipe, which must be
fitted to connection flange A. Fig. 1.
• For the extractor version this pipe must have a diameter of 150 mm.
Should there already be a pipe of diameter 125 mm that ducts to
the outside through the walls or roof, it is possible to use the 150/
125 mm reduction flange provided. In this case the hood will be
slightly more noisy.
Filter version
• The air is filtered through an activated charcoal filter and returned to
the kitchen through the top grill of the outlet pipe.
• When the hood is used in the filter version it must be fitted with an
original AEG KF20 activated charcoal filter (see Special accesso-
ries).
• Fix the deflector using two screws Ø 3.5x6.5 mm. Fig. 2.
• Optionally, the position of the chimney elements can be changed.
When using the hood in the filter version the chimney must be fixed
at the top, with the air outlet grill at the side.
Fig. 1
59