AEG Competence 6292D-M Instruções de utilização e de instalação - Página 8
Procurar online ou descarregar pdf Instruções de utilização e de instalação para Campânula de ventilação AEG Competence 6292D-M. AEG Competence 6292D-M 18 páginas.
immediately to its normal functioning.
The "automatic stop timer" delays stopping of the hood, which will continue
functioning for 15 minutes at the operating speed set at the time this function is
activated.
Troubleshooting
Problem
Hood doesn't work
Poor airflow
Motor running but no
air flow
Motor cuts after a few
minutes
Strong cooking smell
Oil dripping onto stove
Whirring sound
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR EVENTUAL
DAMAGES CAUSED BY BREACHING THE ABOVE WARNINGS.
Possible reason
No electric supply
Aluminum grease filters
clogged
Charcoal filters clogged
Butterfly valve jammed
High temperature safety
device activated
The hood is installed too
near the cooking stove
Charcoal
filters
installed
Oil cup missing or not
installed
Aluminum grease filter
saturated
Something
in
contact
with fan blade
Solution
Check the plug is connected
Check the main switch is turned on
Clean the filters and replace when dry
Replace the charcoal filters
Contact technician
The
kitchen
ventilated
The hood must be least 65cm from
stove
not
In re-circulating mode, charcoal filters
must be installed
Remove aluminum filter and replace oil
cup
Wash the aluminum grease filters
Contact with technician
is
not
sufficiently
8