Part B: Attachment of ECU4 Containment Envelope to Frame
1. Unfold ECU4 containment envelope and place inside opened ECU4 Frame.
On each corner at the top of the ECU4 envelope there are 4 Velcro cuffs.
Position and attach the Velcro cuffs on the post above the locking corner slides as in (Fig. B-1) using
the following guide to manage envelope length v ersus ceiling heights:
For ceiling heights above 10'6" Use top loop
For ceiling heights approximately 9' Use top and second loop from top
For ceiling heights approximately 8' Use top, second and third loop from top
For ceiling heights below 7'8" Use bottom loop position all four above corner locks
2. Attach the remainder of the white Velcro loops along edges of ECU4 envelope to
Outer Legs of the ECU4 frame to the floor. (Fig. B-2) NOTE: This is advised to be done once the unit height
is adjusted.
3. Attach Velcro cu s to each of the four oor trusses. (Fig. B-3). Note: envelope should be stored on the frame
with only the Velcro loops attached above the four locking slider corner w/ring pulls as in (Fig: B-1).
4. Secure the top edge of the envelope to the upper folding truss. The envelope has a sewn in Velcro loop
and the upper truss has Velcro Hook applied to the inside edge of the truss. (Fig: B-4)
X
(Fig. B-1)
(Fig. B-3)
www.mintie.com
X
1-800-9MINTIE
1-323-225-4111
X
(Fig. B- 2)
(Fig. B-4)