RS-232 Commands
COMMAND
GET CHROMAKEY N1 RANGE 8
SET IN N1 HPOSITION N2 8
GET IN N1 HPOSITION 8
SET IN N1 VPOSITION N2 8
GET IN N1 VPOSITION 8
SET IN N1 WIDTH N2 8
GET IN N1 WIDTH 8
SET IN N1 HEIGHT N2 8
GET IN N1 HEIGHT 8
SET IN N1 UP-SIDE DOWN N2 8
GET IN N1 UP-SIDE DOWN 8
SET IN N1 FLIP N2 8
DESCRIPTION & PARAMETERS
Show the current key range set for the selected color component.
Available values for N1:
RED
[Red component]
GREEN [Green component]
BLUE
[Blue component]
Set the horizontal position of the upper-left corner of input N1's window in pixels. The
maximum position value is the current horizontal resolution minus 1.
N1 = 1 ~ 2
N2 = 0 ~ {Resolution-1}
NOTE: Only available in dual-windowing modes.
Show the current horizontal position of the upper-left corner of input N1's window in
pixels.
N1 = 1 ~ 2
[Input port]
Set the vertical position of the upper-left corner of input N1's window in pixels. The
maximum position value is the current vertical resolution minus 1.
N1 = 1 ~ 2
N2 = 0 ~ {Resolution-1}
NOTE: Only available in dual-windowing modes.
Show the current vertical position of the upper-left corner of input N1's window in pixels.
N1 = 1 ~ 2
[Input port]
Set the horizontal size of input N1's window in pixels. The maximum value is the current
horizontal resolution.
N1 = 1 ~ 2
N2 = 0 ~ {Resolution}
NOTE: Only available in dual-windowing modes.
Show the current horizontal size of input N1's window in pixels.
N1 = 1 ~ 2
[Input port]
Set the vertical size of input N1's window in pixels. The maximum value is the current
vertical resolution.
N1 = 1 ~ 2
N2 = 0 ~ {Resolution}
NOTE: Only available in dual-windowing modes.
Show the current vertical size of input N1's window in pixels.
N1 = 1 ~ 2
[Input port]
Enable or disable the vertical flip function for input N1.
N1 = 1 ~ 2
[Input port]
Available values for N2:
ON
[Enable]
OFF
[Disable]
Show the current vertical flip state for input N1.
N1 = 1 ~ 2
[Input port]
Enable or disable the horizontal flip function for input N1.
N1 = 1 ~ 2
[Input port]
Available values for N2:
ON
[Enable]
OFF
[Disable]
9
RS-232 & Telnet Commands
[Input port]
[Horizontal position]
[Input port]
[Vertical position]
[Input port]
[Horizontal size]
[Input port]
[Vertical size]