Kohler Elosis 18077T-B-CP Manual de instruções de instalação - Página 11

Procurar online ou descarregar pdf Manual de instruções de instalação para Luminárias de casa de banho Kohler Elosis 18077T-B-CP. Kohler Elosis 18077T-B-CP 12 páginas. Sensor faucet

Kohler Elosis 18077T-B-CP Manual de instruções de instalação
常见故障排除
以下部分故障现象可通过指示灯闪烁情况识别。(参考"感应指示灯的各种闪烁情况")
不出水
(感应指示灯不闪烁)
感应指示灯每2秒快速
闪烁1次而不出水
感应指示灯闪烁
不出水
感应指示灯闪烁
出水量小
约1分钟以内不止水
(感应指示灯不闪烁)
如按以上操作仍未解除故障,请与销售商或科勒(中国)投资有限公司联系。
除安装更换电池外,请勿随意拆卸龙头其它部件。
TROUBLE SHOOTING
Some trouble symptoms can be identified by the indicator's flashing.
Symptoms
No water flow
(Indicator not flashing)
The indicator flashes once
every 2 seconds and the
water doesn't flow out.
No water flow while
the indicator flashes
Low water flow while the
indicator does not flash
Keep water running within 1
minute while indicator does
not flash
Please contact with distributor or Kohler China Investment Co., Ltd., if the trouble remains after above-mentioned actions are
taken.Please do not disassemble the other parts of the faucet freely except installing and replacing batteries.
1248536-T01-C
无电池或电池装反(直流电)
无电源或接线有误(交流电)
感应范围内有其它物体
感应窗口较脏
接线端未插好、插错
电池耗尽(直流电)
刚刚停电 ( 交流电 )
直流或交流接线端接触不良 ( 交流电 )
刚装机完毕
角阀关闭
过滤装置堵塞
起泡器堵塞
角阀是否彻底打开
起泡器堵塞
过滤装置堵塞
水压太低
感应范围内有物体
Probable Causes
No battery or battery wrongly installed
No power supply or wrong connection
Object in sensing range
Dirt on the sensing window
The connector does not connect well
Batteries are out of power
Power shut-down
DC or AC connector may not connect well
Just finishing installation
The stop valve is closed
The filter is blocked
The Aerator
is blocked
The stop valve is not open completely
The Aerator
is blocked
The filter is blocked
The supply water pressure is low
Object in sensing range
处理方法
检查电池
检查总电源和接线情况
移开物体
清洁窗口
检查接线端
更换电池
检查总电源
重新连接接插件
等待2分钟
打开角阀
清洗 过滤装置
清洗起泡器
打开角阀
清洗起泡器
清洗过滤装置
检查供水系统
移开物体
(Refer to "Note of the Indicator Flashing")
Corrective Action
Check the batteries
Check the power supply and the conncetion
Remove the object
Clean the sensing window
Check the connector
Replace batteries
Check the power supply
Reconnect the connector of AC/DC transformer
Wait for 2 minutes
Open the angle valve
Clean filter
Clean
Aerator
Open the angle valve
Clean
Aerator
Clean filter
Check the water supply system
Remove object
11