Kohler K-1224-HB Manual de montagem - Página 2

Procurar online ou descarregar pdf Manual de montagem para Luminárias de casa de banho Kohler K-1224-HB. Kohler K-1224-HB 4 páginas. Custom bath whirlpool

Pump/Control
Access
20" (50.8 cm) W x
15" (38.1 cm) H
18"
(45.7 cm)
1-11/16"
(4.3 cm)
3-1/2"
(8.9 cm)
Product Information
Applicable product:
Drop-in rim style with heater, custom pump
Fixture*:
Bathing well:
Basin area, bottom
48" (121.9 cm) x 24" (61 cm)
Basin area, top
59" (149.9 cm) x 30" (76.2 cm)
Weight
115 lbs (52.2 kg)
To overflow:
Water depth
14" (35.6 cm)
Capacity
67 gal (253.6 L)
* Approximate measurements for comparison only.
Drop-in cutout dimensions:
64" (162.6 cm) x 34" (86.4 cm)
V
Pump: 1-speed
120
Heater: 1.5 kW
120
Minimum access panel
pump/control (required):
1014718-1-B
7-1/2" (19.1 cm)
Max
8-11/16" (22.1 cm)
66" (167.6 cm)
1" (2.5 cm)
2-7/8"
(7.3 cm)
3"
(7.6 cm)
K-1224-HB
Hz
A
60
7.5
60
12.5
20" (50.8 cm) W x
15" (38.1 cm) H
No change in measurements if connected with drain
illustrated. (K-7161-AF or K-7161M-AF)
Recommended Faucet Area
20"
18-1/2"
(50.8 cm)
(47 cm)
Required Electrical Service (2 required)
Two dedicated circuits required, each protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
Heater
Locate the outlets behind the whirlpool and within 24" (61 cm)
of the pump and heater.
Notes
Install this product according to the installation guide.
Floor support under this product must provide for a minimum of
43 lbs/square foot (208 kg/square meter) loading.
The apron must be installed before the finished floor and wall
materials are installed.
If installing a rim-mount faucet, make sure there is no interference
with the drain overflow and circulating system before drilling any
holes. Consult local and national codes for minimum air gap
requirements if installing a spout on the faucet deck.
Pump must be relocated to custom position at the time of
installation. Provide adequate clearance.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions
are nominal.
2
1-1/2"
(3.8 cm)
Drop-in Rim
Detail
35-7/8" (91.1 cm)
1-1/2" OD
120 V, 15 A, 60 Hz
120 V, 15 A, 60 Hz
Kohler Co.