Ceiling
Apply
sealant tape.
Elbow
Apply
plumbers putty.
Install the Showerhead
NOTE: The shower arm with flange are not provided.
Remove the existing showerhead and shower arm, if applicable.
Install the shower elbow. Make sure the elbow is securely
mounted and has adequate strength to support the showerhead.
Apply a bead of plumbers putty or other sealant to the back of
the flange.
Place the flange onto the long end of the shower arm, as
illustrated.
Apply sealant tape to the threads of each end of the shower arm.
Install the shower arm to the shower elbow.
Use a clean strap wrench to tighten the arm onto the elbow.
Press the flange against the finished wall/ceiling.
Secure the flange to the shower arm by tightening the setscrew.
Remove any excess putty.
Turn on the water to flush any debris through the shower arm.
Turn off the water.
Handtighten the showerhead to the shower arm.
Use a clean strap wrench to completely tighten the showerhead.
Check all connections for leaks.
Kohler Co.
Wall
Apply sealant tape.
Flange and
Setscrew
(not included)
Shower Arm
(not included)
Showerhead
3