Important Information

Read all instructions before using or installing this product.
WARNING: When using electrical products, basic precautions should always be followed,
including the following:
DANGER: Risk of electric shock. Connect only to a circuit protected by a ground-fault
circuit-interrupter (GFCI) or residual current device (RCD). Grounding is required. The unit should
be installed by a qualified service representative and grounded.
WARNING: Risk of electric shock. A licensed electrician must route all electrical wiring and
connections for this product. Improper installation will create an electrical hazard and may not
comply with local building and electrical codes.
WARNING: Risk of electric shock. Disconnect power before servicing.
WARNING: Risk of injury or property damage. Please read all instructions thoroughly before
beginning installation, including the following requirements.
WARNING: Risk of property damage. Building materials and wiring should be routed away from
the blower motor body and other heat-producing components of the unit.
NOTICE: Follow all local plumbing and electrical codes.
NOTICE: An access panel is required to service the pump/control. The access panel size must be a
minimum of 20" (50.8 cm) in width, and 15" (38.1 cm) in height.
Save these instructions.

Product Information

Electrical Requirements

WARNING: Risk of burns, fire, electric shock, or injury to persons. Do not operate the pump if
the pump supply cord is damaged. For proper guidance to have this product repaired, please call:
1-800-4-KOHLER from within the USA, 1-800-964-5590 from within Canada, or 001-877-680-1310
from within Mexico.
The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device
(RCD). The GFCI or RCD protects against line-to-ground shock hazard. Use a 120 V, 15 A, 60 Hz dedicated
service for the bath with airjets.

Product Notices

NOTICE: Keep the area around the blower motor clean and free of debris. Ensure that the area around the
blower motor is free of sawdust, insulation, dirt, or other small loose debris. Such material could clog the
blower motor air ducts and reduce the air flow through the blower.

Factory-Assembled Features

Factory installed components include blower motor with power supply cord, check valve, air piping, user
keypad, and keypad cable. Other than power wiring and plumbing, no assembly is needed.
1040292-2-E
2