1. In case of low use: 12 months.
2. The period of time that must elapse before checking
the filter element depends on the environment in which
the engine operates. The air filter must be cleaned and
replaced more frequently under very dusty conditions.
3. In case of low use: 36 months.
6. Contact authorized KOHLER workshops.
7. The replacement interval is only an indication, it strongly
depends from environmental condition and hose status
detected during regular visual inspection.
5.3 Oil level check
1. Loosen the oil filler cap A. Remove the oil dipstick B and
check that the level is up to MAX.
2. Pour in recommended oil until reaching the MAX level
mark.
3. Reinstall the oil dipstick B completely.
4. Re-tighten the cap A and/or C.
• Do not use the engine with the oil level below the minimum.
5.4 Oil dipstick on cylinder head
A
5.2
5.5 Air filter check
NOTE:
Components not necessarily supplied by
KOHLER.
1. Release the two clasps D of the cover A.
2. Remove the cartridge B.
3. Clean the inside components A and C with a damp cloth.
4. Do not use compressed air, repeatedly tap the front side
E on a flat surface.
5. Reinstall:
- cartridges B.
- the cover A checking the right tightness of clasps D.
EN
24
INFORMATION ABOUT MAINTENANCE
Important
C
8. The first check must be done after 10 hours.
9. Test the coolant condition annually with coolant test
strips.
10. It is recommended to have SCA (Supplemental Coolant
Additives) added at the first maintenance interval.
11. Read Cap. 2.5, "KDI Mechanical Injection Uncertified
Engines (no EGR Engines)"
B
5.1
B
5.3
A
D
E
B
5.5
B
MAX
MIN
B
MAX
MIN
5.4
C
ED0053029510
_14