Dosing Speed [ SPEEd ]
You may adjust the dosing speed to prioritize either the accuracy or the speed of dosing. There are
three speed settings available:
1. PrEC — Precision: Default speed, high accuracy. (default)
2. FASt — Fast: Faster speed, default accuracy (227 grams within 12 seconds); recommended for
doses of 100 grams or more.
3. GrEEn — Green Bean: Default speed for green beans or light roast beans.
To save your selection and exit the settings sub-menu, press Dose. [ SPEEd ] will display on the LED
to confirm that the selected option has been saved.
Zero Tracking Setting [ trAcE ]
Zero Tracking is a function to help compensate the weight readout fluctuations at zero point to
improve the usability of the scale. The Acaia Orion is allowed to compensate fluctuations by up to 2d
according to industrial weighing guidelines.
1. Off: It is not recommended to turn off Zero Tracking; the zero indication can drift easily as the room
temperature changes.
2. 0.5 d~3 d: For example, since each division is 0.1 g, 3 d = 0.3 g. When Zero Tracking is set to be 3
d, any initial weight between +/- 0.3 g on the weighing pan will be zeroed out.
3. 2 d is recommended in general for the Orion.
To save your selection and exit the settings sub-menu, press Dose. [ trAcE ] will display on the LED
to confirm that the selected option has been saved.
Key Sound Setting [ bEEP ]
1. Set the Key Sound function to Off/On to turn off/turn on the beeping sound.
To save your selection and exit the settings sub-menu, press Dose. [ bEEP ] will display on the LED
to confirm that the selected option has been saved.
Default Weighing Unit [ Unit ]
1. The Default Weighing Unit is set to grams if [ 9 ] is selected and ounce if [ o2 ] is selected.
2. Rotate Dial to switch the Default Weighing Unit between grams and ounces.
To save your selection and exit the settings sub-menu, press Dose. [ Unit ] will display on the LED to
confirm that the selected option has been saved.
Cup Detection [ CUP.d ]
1. The default setting is on.
2. On: Cup detection enabled. Orion will check if there is a container on the weighing platform. If no
container is detected, Orion will not start dispensing the coffee beans.
3. Off: Cup detection disabled. Orion will start dispensing the coffee beans even if no container is
detected.
Calibration [ CAL ]
Please go to Page 5: Calibration for more information.
About [ About ]
Shows the current Orion Firmware version.
To update to the latest version, please use Orion Updater on www.acaia.co/pages/apps.