10 TROUBLESHOOTING
Problem
Blower fan and
motor do not start
Insufficient airflow
Pulse cleaning not
working
10
Probable cause
Not wired correctly
Electrical supply
circuit down
Fan rotation backwards
Access doors open
or not closed tight
Filter plugged
Dust storage area
overfilled or plugged
Compressed air
not is connected
Solenoids are not
wired properly
Defective solenoids
Single shot timer failure
Downdraft work benches and tables
Solution
Check if the unit is plugged.
Check and correct motor wiring for supply voltage. See
motor manufacturer's wiring diagram. Follow wiring
diagram.
Check power supply circuit for proper voltage. Check
for fuse or circuit breaker fault. Replace as necessary.
Proper fan rotation is clockwise from the top of the unit.
The fan can be viewed through the back of the motor.
Check that all access doors are in place and secured.
Check the filter. Clean or replace if needed.
Empty and replace the dust drawer when 2/3 full.
Check the compressed is connecting to the table.
The pressure must be between 80-90 PSI.
Check wiring between the single shot timer
and solenoids.
Check if solenoids work properly.
Check the wiring diagram and verify all wires are
correctly plugged. The timer must be set at 100ms.