Aqua Comfort ACT-1500T7S Manual do Proprietário - Página 10
Procurar online ou descarregar pdf Manual do Proprietário para Aquecedor de piscina Aqua Comfort ACT-1500T7S. Aqua Comfort ACT-1500T7S 13 páginas. Heat pump pool heaters
"LPS" (Compressor Low Pressure)
• Evaporator coil dirty.
• Fan motor not running.
• Low refrigerant pressure.
• Defective low-pressure switch.
• Low ambient air temperature.
"ESO"
• Evaporator temperature sensor connection opened. Check for cut or loose sensor wiring
or defective sensor.
"tSO"
• Water temperature sensor connection opened. Check for cut or loose sensor wiring or
defective sensor.
"ESS"
• Evaporator temperature sensor connection shorted. Check for a short in sensor wiring or
defective sensor.
"tSS"
• Water temperature sensor connection shorted. Check for a short in sensor wiring or
defective sensor.
"DEF"
• Heat pump in defrost cycle.
CALLING FOR SERVICE
• Visit www.aquacomfort.com, click "Service" and complete the Service Request form.
• Please eliminate any water flow problems before calling for service.
• If you are unable to contact the installing agent, please contact AQUACOMFORT
TECHNOLOGIES, LLC. A factory representative will assist you or your serviceman
over the phone.
SERVICE PERFORMED WITHIN THE WARRANTY PERIOD MUST BE APPROVED BY AQUACOMFORT
TECHNOLOGIES, LLC. PRIOR TO SERVICE BEING PERFORMED AND ONLY BY AN AQUACOMFORT
TECHNOLOGIES, LLC. AUTHORIZED TECHNICIAN. SEE WARRANTY FOR DETAILS.
Please have the following ready before calling:
MODEL #:
SERIAL #:
DATE OF INSTALLATION:
NAME OF OWNER:
ADDRESS:
CONTACT #:
NATURE OF PROBLEM:
10