Dexter Laundry T1200 Instruções de instalação e operação - Página 7

Procurar online ou descarregar pdf Instruções de instalação e operação para Máquina de lavar roupa Dexter Laundry T1200. Dexter Laundry T1200 18 páginas. 75lb capacity computer control opl washer
Também para Dexter Laundry T1200: Manual de instalação e operação (18 páginas), Livro do proprietário (16 páginas)

Dexter Laundry T1200 Instruções de instalação e operação

EMERGENCY STOP / SAFETY DOOR LOCK

This machine is equipped with a Safety Door Lock that locks the door closed from when the
cycle is started until the cycle is complete. The door lock prevents opening the door for up to 3
minutes if the power is interrupted during the cycle.
The Emergency Stop button pauses the washer and allows the door to be opened during the cycle
after the Safety Door Lock releases. When the Emergency Stop button is pressed an alarm will
sound and the display will begin counting down from "3". If the button is released before 3
seconds elapse, the alarm will stop and the cycle will continue normally. If the Emergency Stop
is held down for 3 seconds, the display will count down to "0" and the washer will begin
stopping movement and water flow and begin draining water from inside the washer. Though
the machine may stop wash movement quickly, it may take up to 3 minutes for the door to
unlock. During that time the alarm will continue to sound. When the alarm stops, the door may
be opened. The washer may be restarted by closing and latching the door, and pressing the Start
button. If the washer was stopped more than once before the final extract, the cycle will be
cancelled. If the washer was stopped during final extract, the cycle will be ended. If the washer
is stopped for more than 1 hour, the cycle will be terminated.
MODEL
CAPACITY
CYLINDER SIZE
ELECTRICAL
DRIVE SYSTEM
WASH SPEED
INTERMEDIATE
EXTRACT
FINAL EXTRACT
MACHINE CONTROL
WATER INLET

DRAIN VALVE

SPECIFICATIONS

80LBS/11.5 CUBIC FT. (36.3 kg/325 l)
30" DIA X 28" DEEP (76cm X 71cm)
208-240 VAC, 60 HZ, 1 OR 3 PHASE
SOFT START REVERSING INVERTER DRIVE
43 RPM
375 RPM (60 G'S)
485 RPM (100 G'S)
PROGRAMMABLE COMPUTER
4 SOLENOID OPERATED VALVES
FLOW RATE: 2 DUAL VALVES (9 GAL/MIN) EACH, 30-120 PSI
2 SINGLE VALVES (12 GAL/MIN) EACH, 30-120 PSI
3" DIAMETER
T1200 80LB WASHER