Tidalwave Resistance Adjustment Instructions
After riding the Tidalwave Pool Bike a few times (and all the components get broken in) users may i nd
the need to reset the resistance. To do this:
- Set the resistance adjustment knob to the lowest setting by turning the knob counterclockwise.
- Slightly loosen the screw, using a phillips screw driver, on the back of the frame that connects to the
resistance adjustment knob. See FIG. 13 below.
- Slide the resistance adjustment knob assembly up the frame (towards the seat) within the slotted hole.
Very slight movement should be all that is necessary. See FIG. 14 below.
- Retighten the screw on the back of the frame.
- Test the new resistance level.
- Repeat these steps as many times as necessary until a comfortable tension is set.