A.H. Systems SAS-563B Manual de operação - Página 11
Procurar online ou descarregar pdf Manual de operação para Antena A.H. Systems SAS-563B. A.H. Systems SAS-563B 14 páginas. Active loop antenna
Também para A.H. Systems SAS-563B: Manual de operação (13 páginas)
A.H. Systems Model EHA-51B Active Monopole and Loop Antenna
CALCULATIONS
EMISSIONS TESTING
Individual calibration data for the active loop antenna is supplied to comply
with various emissions test requirements. For emissions measurements, add
antenna factor plus cable loss to receiver reading in dBV to convert to field
strength in dBA/meter.
Field Strength(dBuA/m) = SA(dBuV) + MAF(dB/m) + cable loss (dB)
Fictitious electric field strength can be calculated by the following:
A.H. Systems inc. – Oct 2017
REV B
SA = Spectrum Analyzer or Receiver voltage reading
MAF = Magnetic Antenna Correction Factor
CL = Cable Loss in dB
dBV/m = dBA/m + 51.5
11