INSTALLATION AND MAINTENANCE MANUAL
PERSONAL SAFETY
Ensure reel has been properly installed before connecting supply line.
Before connecting to reel, be certain supply line does not exceed
rated pressure of the hose reel or amperage rating on cable reel.
Thoroughly review the "Hose Installation" instructions to properly
install hose.
MOUNT REEL / FASTEN CRANK HANDLE
To mount reel to a solid structure use 7/16" or M12 bolts, washers,
and nuts. Masonry bolts may be used depending on mounting
application. Mounting hardware is NOT provided. Mounting patterns
will vary depending on model. NOTE: If you choose to permanently
mount series CM, you will need four ¼" screws or nails.
Fit mounting hardware to ceiling/wall/floor so reel can be fastened
into position. Fit reel and tighten all hardware securely.
Reels are supplied with plastic crank handle uninstalled. Remove
handle and hardware from plastic bag and install onto crank arm.
Models 1275 and 600-900 will include detachable crank for bevel
gear design.
The series DM portable reels will include a U-shaped handle. Position
handle over swaged posts and fasten using hardware provided.
INSTALLATION OF INLET HOSES
Apply thread sealant to inlet hose and connect to the swivel joint on
reel.
CAUTION: IT IS IMPORTANT TO USE A "FLEXIBLE" INLET HOSE.
DO NOT USE SOLID PIPING OR RESTRAIN INLET HOSE AS TO
CAUSE ANY SIDE FORCE ON SWIVEL JOINT. THE WARRANTY
IS VOID IF NOT PROPERLY INSTALLED.
Flush some product through the system before connecting inlet hose to
the source.
Connect end to supply source.
OPERATIONAL CHECK
CAUTION: ENSURE THAT ALL OPERATION CHECKS HAVE BEEN
COMPLETED BEFORE RELEASING FOR USE
Adjust drag brake. Turn clockwise to add tension and counter-
clockwise to decrease tension. See figures 3.0-6.0.
Check for correct operation by pulling out some of the hose/cable. A
slight friction or drag should be noticed. This drag is to prevent
backlash when pulling out hose/cable.
Fit hose to swivel then fit swivel to reel.
For assembly drawings, parts lists, or specific repair instructions, refer to web site at
Coxreels, Inc., 5865 S. Ash Ave., Tempe, Arizona, USA, 85283

INSTALLATION

OPERATIONAL CHECKS

NOTE: Swivels designs vary depending on the reel model. Refer to repair
procedure shipped with individual seal replacement kits or consult factory.
Page 3 of 4
Perform "Operational Check" per instructions to ensure reel is
operating properly.
If a leak should occur after applying pressure to the reel, immediately
discontinue supply line pressure.
WARNING: Prevent static sparking. When working around flammables,
ensure that the hose reel, hose, and equipment are properly grounded.
INSTALLATION OF OUTLET HOSE
NOTE: Before proceeding, ensure that you are installing the proper
size, length and type of hose that the reel is rated for. Consult factory if
unsure of rating.
Securely install hose reel prior to installing outlet hose.
Apply thread sealant to male hose fitting and insert into the drum
opening. Note: It is recommended that a swivel type connector be
used to ease installation of outlet hose.
Thread male hose fitting into outlet riser(s) (Refer to FIGURE 1.0).
Challenger series 112, 117, CM, DM and SM, outlet will be inside drum
area. Note: Outlet riser is removable on 1195 series.
Using a wrench, firmly hold on to riser fitting while tightening hose
connector.
The Series 100 reel includes a hose clamp. Fasten hose securely to
reel with hose clamp provided.
NOTE: The hose clamp restrains the hose when fully extended,
preventing strain on the fitting.
CAUTION: FULLY EXTEND AND CHARGE HOSE BEFORE
INITIALLY WINDING ON TO REEL. THIS PREVENTS FLATTENING
OF HOSE AND EXCESSIVE PRESSURE ON DRUM WHEN HOSE IS
FULLY CHARGED DURING OPERATION
SWIVEL SEAL REPLACEMENT
Remove inlet hose from swivel.
Remove swivel from reel by unscrewing swivel from reel axle.
Disconnect hose from swivel.
Remove retaining ring on swivel; pull out spool from body.
Fit hose to swivel then fit swivel to reel.
DO NOT OVER TIGHTEN!
Reconnect inlet hose and test for leakage.
CAUTION: Release line pressure prior to making repairs or
adjustments to reel.
www.coxreels.com
Tel: 1-800-269-7335
FORM #PM-129 REV - 12/10
or consult factory.