MIRACLE STEAMER
Hi-Limit Reset Button
Power Cord
Figure 5. Hi-Limit Reset Button
READY
UP
POWER
Figure 6. "ERR" Fault Code
A.J. Antunes & Co.
OPERATION (continued)
Cap
ERR
SINGLE SHOT
DOWN
PRGM
START/STOP
Hi-Limit Reset Button
A hi-limit thermostat turns off electrical power to the
steam generator if it overheats. To reset this thermo-
stat, allow approximately 45 minutes for the unit to cool
down, remove the black cap, and then press the black
reset button located on the rear of the unit (Figure 5).
If the unit requires continuous resetting, contact your
Authorized Service Agency.
Status Indicator LEDs
The Miracle Steamer's Control Board has four status
indicator LEDs described below:
Green (Program): When lit, indicates the unit is in
Program mode.
Yellow (Audio): When lit, indicates 10-15 VDC is being
supplied to the audio signal. The audio signal sounds
and the LED lights for approximately 3 seconds.
Red (Heat): When lit, indicates the Control Board is
calling for heat by supplying 10-15 VDC to the Solid
State Relay. When off, indicates that the unit is
satisfied.
Green (H2O): When lit, indicates that 24 VAC is being
supplied to operate the water pump, This LED is only
lit for approximately 1 second.
Fault Codes
When the programming parameters for Minutes/
Seconds/SHO/H2O have been inadvertently changed
below or above their limits, the unit displays the "ERR"
fault code (Figure 6). If this code appears, clear these
settings using the procedure below:
1. Turn the unit off.
2. Press and hold the PROGRAM and START/
STOP buttons simultaneously.
3. Turn the unit on while holding the appropriate
buttons. Release the buttons when the unit stops
beeping,
4. The display will now register the cycle time.
NOTE: Repeat these steps if the unit still displays
the "ERR" fault code.
NOTE: It is recommended that the SHO and H2O
settings be adjusted to the recommended settings
shown in the Programming section of this manual.