Aqua Flo AQUV-20 Manual do Proprietário - Página 10
Procurar online ou descarregar pdf Manual do Proprietário para Sistemas de filtragem de água Aqua Flo AQUV-20. Aqua Flo AQUV-20 16 páginas. Ultraviolet disinfection system
(E) DISINFECTION PROCEDURE
Before service begins, all household plumbing lines should be disinfected to prevent the possibility of re-contamination after UV disinfection. You
should also disinfect your plumbing system if the power goes out for several hours or more or if the unit has been accidentally shut-off for several
hours or more. It is advisable to disinfect the plumbing lines at least once a year. Disinfect after using bypass as well.
The following is a general method for disinfection of plumbing lines. If you are uncertain about the
efficacy of this procedure you are advised to contact your local health authority responsible for water
safety.
1. Shut off the supply valve and de-pressurize the lines by opening a tap until it runs dry.
2. Remove the filter in the filter housing and add about 1-2 cups (250-500ml) of unscented household bleach (5 to 6% sodium hypochlorite) to the
empty filter housing and put it back on the filter head.
3. Open the supply valve and slowly open a faucet and let the water run until you can smell the chlorine and then shut the faucet off. Repeat the
procedure for all hot and cold outlets in the house. Add more bleach as required. Run hot faucets longer to allow the chlorine to come through
the hot water tank.
4. Leave the bleach solution in the plumbing system for about 6 to 8 hours preferably overnight.
5. Shut-off the supply valve again and open a faucet to depressurize the system. Open the filter housing and re-install the filter cartridge and then
re-attach the filter housing. Make sure that the UV system is ON.
6. Take off aerators (if any) on the faucets, open the supply valve slowly, and thoroughly flush all outlets until the chlorine smell is minimal.
7. You are ready to use the water now.
(F) BALLAST FOR AQUV UV SYSTEMS
The Aqua Flo AQUV advanced micro-processor controlled electronic UV ballast is for use all Aqua-Flo AQUV systems. It features both audio and visual
alarms to indicate the lamp operation and an integral annual lamp change reminder timer.
NORMAL DISPLAY: Number of days left before lamp expires and must be
replaced. Starts at 365 and ends at 0.
Press button to display the total running days of the unit since installation
10
(maximum 9999 days). Display goes back to default after 10 seconds.
"LF" - LAMP FAULT: If the lamp is disconnected or defective (burned out), the
display will show "LF" with the red LED on, and the ballast will beep every 2
seconds. If you press the button once, display will show "lamp life remaining" and go back to
"LF" after 10 seconds. If you press the button again before 10 seconds, display will show "total running time" and then after 10 seconds go back to
"LF". In the "LF" alarm do not consume water until you replace UV lamp and cleared the alarm.
15. Remove the nut from the ground stud at the top of the unit. Next place the
ground wire (green wire with yellow stripes) over the stud and tighten the nut.
16. Connect the ballast power cable to the AC supply (with surge protector). The
green lamp-on LED will light up and the display will show "365". This number
indicates the number of days left until lamp life expires and must be replaced.
Follow Step (E) before consuming water.
YOUR AQUA FLO AQUV UV DISINFECTION SYSTEM IS NOW READY FOR SERVICE.
WARNING
Failure to follow disinfection procedure could result in
micro-biologically unsafe water leading to potential
illness or death.
DISPLAY
BUTTON RED LED
GREEN LED