Deye SUN-5K-SG Manual de reparação - Página 9
Procurar online ou descarregar pdf Manual de reparação para Inversor Deye SUN-5K-SG. Deye SUN-5K-SG 17 páginas. 5kw storage inverter
5KW Storage Inverter Repairing Guide
Grid frequency out of range
1. Check the frequency is in the range of specification or not;
2. Check whether AC cables are firmly and correctly connected;
3. Seek help from us, if can not go back to normal state.
Error
F-49/ 46
Description
Backup battery fault.
1. Check the battery capacity;
2. Check the connection between batteries and inverters;
3. If inverter can't go back to normal after load reduction, seek help from us
Error
F-50
Description
No related to this machine
Error
F-51
Description
No related to this machine
Error
F-52
Description
No related to this machine
Error
F-53
Description
No related to this machine
Error
F-54
Description
No related to this machine
Error
F-55
Description
1. Check whether PV voltage is too high or battery voltage is too high.
2. If the PV voltage is too high, reducing the number of PV panel in series
3. Seek help from us, if cannot go back to normal state
Error
F-56
Description
Battery voltage low
1. Check whether battery voltage is too low;
2. If the battery voltage is too low, using PV or grid to charge the battery;
3. Seek help from us, if can not go back to normal state.
Bcakup_Battery_Fault
V phase grid current DC component over current
W phase grid current DC component over current
AC inductor B, phase current DC current high
Read the memory error
AC inductor C, phase current DC current high
DC busbar voltage is too high
DC busbar voltage is too low