AQUA FORTE EcoMax Instruções
Procurar online ou descarregar pdf Instruções para Bomba de água AQUA FORTE EcoMax. AQUA FORTE EcoMax 4 páginas.
______________________________ English__________________________________
Read these instructions carefully before starting to install this equipment.
Safety
1. Always pull the plug out of the mains socket when carrying out repair or maintenance work.
2. Never operate the pump while there are people in the water.
3. The pump uses blades to propel the water, and these blades revolve at a high speed. Ensure that you keep your fingers or any other
parts of the body away from the revolving blades.
4. Do not use the unit if it or its component parts are damaged.
5. Ensure that the plug is always dry.
6. As a matter of principle, only used standardised shockproof sockets (Schuko, Home Office sockets).
7. To guarantee safety, always use an earth leakage current trip (FI device) with a response threshold of less than 30 mA.
8. If no suitable connection point is available, or if the connection does not fulfil the requirements, please consult a specialist electrical
installation company.
9. Never carry or pull the pump by the cable.
10. The pump is only suitable for water up to 35°C.
Purpose of use
This pump is only suited for the use in private ponds and not for commercial purposes. Only use the pump for this specific purpose. The
pump is not suited for heavily polluted water, or water with heavy abrasive parts (like sludge).
Warranty
You have made an excellent choice in purchasing this product. The unit has been carefully assembled in compliance with all safety
instructions. To ensure the highest possible quality of the product, the supplier has made use of high quality materials, and provides a 2-year
warranty from the date of purchase for material and production faults. Please be aware that the supplier cannot accept any claims under the
guarantee that arise as a result of errors in the installation or operation, incorrect handling, non-compliance with safety regulations,
inadequate maintenance, damage of any kind and the carrying out of any technical modifications of any kind. Guarantee claims can only be
dealt with if the complete product is returned postage-paid and is accompanied by a valid proof of purchase. In case of a claim under the
guarantee, the supplier reserves the right to either repair or completely replace your unit. Consequential damage is excluded from this
guarantee, and the supplier will also provide no guarantee for parts subject to wear, for example, the rotor.
This manual describes the characteristics and the maintenance of an EcoMax pump.
- Energy saving 230V A-synchronous motor
- Vortex impeller
- Thermal protection against over current
- Pump cover removable without tools.
- Suited for waste parts up to 6mm
- Removable impeller makes maintenance easy.
- All electrical parts are casted in resin.
- 10m rubber cable with earthed Schuko plug
Box content: O-series: Pump with 2 x hose tail fittings (diameter 19-25-32-40mm) of which one is 360°adjustable.
M & P series: female threaded adapter. HF Series: no fittings.
Installation
The pump is suited for both wet and dry applications (HF pump models are not suited for dry application). In a dry setup the pump must be
under water level as it is not self-priming. For dry setup the external strainer house must be removed for the connection of the pipe fittings.
Use without water (dry running) will result in irreparable damage. Under water, the pump must take in as clear as possible water. Never place
the pump in a muddy area or on sandy pond bottoms. Put the pump on a small pedestal (e.g. a stone). Ignoring these instructions can cause
blockage of the strainer house around the pump. Heavily polluted water will cause problems for the rotor to run smooth and the pump
performance will decrease. In a worst case scenario the rotor will totally Block and the pump will burn out. Complete blockage of the pump
strainer house will prevent motor cooling which can cause burn outs.