AQUA FORTE SC998 Manual do utilizador e de serviço - Página 13
Procurar online ou descarregar pdf Manual do utilizador e de serviço para Bomba de água AQUA FORTE SC998. AQUA FORTE SC998 16 páginas. Mini heat pump for swimmingpool
Condensate drain is normal or not;
Are there any abnormal sound or vibration during running.
2. Control Function Description
2.1.
The buttons of LED wire controller
2.2.
Controller display instructions
The red light lights up when heating mode
The green light flashes when defrosting
2.3.
Definition of function keys
2.3.1 "
" key
Under the main interface, press this button to turn on or off the heat pump.
Under the parameter checking interface, press this button to return to the main interface.
2.3.2 "
" and "
" key
▲
▼
Under the main interface, press keys to adjust the current target water temperature.
Combine with "M" to set parameters.
2.3.3 "M" key
Press "M" key for 5 seconds to check the parameters. Press "▲" and "▼" to turn the pages to check
different parameters.
Press "M" key under the parameter-checking status to enter the enter the status of parameters
setting. Press "▲" and "▼" to change the parameter value. Press "M" button to confirm the
parameter value and return to the parameter-checking status.
In shutdown state, long press this button for 5 seconds to switch between Fahrenheit and Celsius.
When the switch is completed, the corresponding temperature mode will be displayed on the main
interface for 3 seconds (Fahrenheit shows F, Celsius shows C).
2.4.
Reset operation
When pressing the "M" key + "
default values.
2.5.
Parameter checking
Press the "Ml" button for 5 seconds to check the parameters. And you can press "▲" and "▼" to turn
the pages to check different parameters.
" key for 10 seconds, the parameter values can be recover to
10