DeZurik 145 Manual de instruções - Página 4

Procurar online ou descarregar pdf Manual de instruções para Controlador DeZurik 145. DeZurik 145 13 páginas. Diaphragm actuator iso mounting

DeZURIK
DeZURIK MODELS 145 AND 250 DIAPHRAGM ACTUATOR ISO MOUNTING

Description

The DeZURIK Model 145 or 250 Diaphragm Actuator is a pneumatic rack-and-gear spring-return rotary
actuator used for on-off or modulating control. The actuator is used on a quarter-turn valve with an ISO
actuator mounting configuration. The Model number-145 or 250-is the actuator size, and designates
the effective pressure area in square inches of the spring-loaded diaphragm. The spring action may be
spring-to-close or spring-to-open, and is reversible without additional parts. A choice of three spring
ranges is available-20, 35 or 60 PSI (140, 240 or 420 kPa).

Installation

One pneumatic signal line connection is required to the ½" NPT port on the end of the actuator. The
pneumatic signal pressure must equal – but not exceed by more than 10 PSI (70 kPa)-the spring rating
of zero to 20, 35 or 60 PSI (140, 240 or 420 kPa) as shown on the actuator label.
For high vibration installations, additional mounting support is recommended on the spring end of the
actuator to prevent damage to the actuator and/or the piping system. Mount the support from the
pipeline to the end of the spring cartridge.

Operation

The actuator is powered pneumatically, and rotates 90 degrees between the open and closed positions.
The action of the actuator is either spring-to-close or spring-to-open, as determined by the orientation of
the diaphragm and the spring cartridge, as shown in Figure 1. The action selected is shown on the
actuator label. With spring-to-close, increasing signal pressure to the actuator opens the valve, and
decreasing pressure closes the valve; with spring-to-open, increasing pressure closes the valve, and
decreasing pressure opens the valve.

Lubrication

The actuator is lubricated at the factory and does not require routine maintenance.

Open and Closed Position Stops

The open and closed position stops are the two hex head cap screws (B23) shown in Figure 1. The
stops are adjustable and prevent the actuator from rotating beyond the open and closed positions of the
valve. If the actuator is factory-mounted on the valve the stops are preset and do not require further
adjustment. If the actuator is not mounted on the valve or if the actuator is removed and/or
disassembled, the stops will require adjustment as described below. Refer to the Valve Instructions for
the closed position requirements and adjust the stops with the actuator mounted on the valve. Refer to
Figure 1 for component identification.
For closed stop adjustment on spring-to-close actuators or open stop adjustment on spring-to-open
actuators:
1. Relieve the air pressure to the actuator.
2. Loosen the jam nut (B24) on the appropriate stop screw (B23). Refer to Figure 1.
3. Turn the stop screw in or out until the valve is in the correct position. The screw will turn easier
if air pressure-just enough to relieve the force on the screw-is applied to the actuator. Relieve
the pressure to check the stop screw adjustment.
4. Hold the stop screw from turning and tighten the jam nut to 230 ± 30 foot founds (312 ± 41 Nm)
if carbon steel or to 140 ± 18 foot pounds (190 ± 24 Nm) if stainless steel.
September 2015
Page 4
D10368