SYMPTOM
External leak
Reduced air flow or a significant
general increase in breathing
resistance in the complete regulator
Impossible to inhale or exhale from the
complete regulator
Water enters the mouthpiece during
inhalation
Table 1. Troubleshooting Guide
POSSIBLE CAUSE
1.The connector or valve support O-rings
are extruded, worn or damaged.
2. The mouthpiece body is cracked
3. The corrugated hoses are worn or
damaged
4. The corrugated hose tightening collars
are damaged or badly tightened
1. The cylinder valve is not completely open
2. The valve needs servicing
3. The first stage filter (10) is blocked
4. The cylinder is empty
1. The valve holders have been fitted the
wrong way round in the mouthpiece
2. The mouthpiece has been fitted
backwards to the corrugated hoses
3. The cylinder valve is not open
4. The cylinder is empty
1. Mouthpiece pierced or broken (1)
2. Diaphragm damaged
3. The connector or valve support O-rings
are extruded, worn or damaged.
4. The corrugated hose tightening collars
are damaged or badly tightened
5. The corrugated hoses are worn or
damaged
Mistral Mouthpiece Service Manual
TREATMENT
1. Replace the O-ring(s)
2. Replace the mouthpiece body
3. Replace the corrugated hoses
4. Replace the collar(s)
1. Open the valve and check the
cylinder pressure
2. Try another cylinder
3. See the Mistral First Stage Trouble
Shooting Guide
4. Charge the cylinder
1. Disassemble and refit following the
correct procedure
2. Disassemble and refit following the
correct procedure
3. Open the valve
4. Charge the cylinder
1. Replace the mouthpiece
2. See the Mistral Second Stage
Trouble Shooting Guide
3. Replace the O-ring(s)
4. Replace the collar(s)
5. Replace the corrugated hoses