DFE TrueView 1100 Manual de instruções - Página 5
Procurar online ou descarregar pdf Manual de instruções para Instrumentos de medição DFE TrueView 1100. DFE TrueView 1100 14 páginas. Tension indicator
![DFE TrueView 1100 Manual de instruções](/uploads/products/server2/290458/290458.jpg)
1
OVERVIEW / DEVICE DESCRIPTION
1.1
GENERAL DESCRIPTION
The TrueView™ 1100 Indicator is a compact, versatile single-channel tension transducer
interface. It can be used with DFE tension transducers to monitor tension in any zone on web
or filament processing machinery. The standard configuration for the 1100TV is a 4.9" x 3.75"
x 1.36" aluminum enclosure with a terminal connector.
1.2
SPECIFICATIONS
Model: 1100TV
Display: 4.3" LCD touchscreen, capacitive, 500 nits brightness
Power Input:
Voltage: 24 VDC +/- 10%
Current: 0.1 ADC typical, internal fusing PTC resettable
Tension Indicator Accuracy: +/- 1/2% drift at ambient maximum
Calibration Range: Up to 50:1
Processor: 32 Bit
ADC Resolution: 16,777,216 (24 Bit)
DAC Resolution: 4,096 (12 Bit)
Tension Outputs: (Simultaneous)
Output 1: 0-10 VDC isolated from 24 VDC input GND
Output 2: 4-20 mA isolated from 24 VDC input GND
Temperature Range: 32°F to 122°F (0°C to 50°C)
Dimensions: 4.9" W x 3.75" H x 1.36" D
Weight: 1.5 lbs (681 g)
Certifications:
1.3
FEATURES
• Full Color Touchscreen: 4.3-inch capacitive touchscreen display for navigation, selection
and adjustment
• 10% or 25% Calibration Ratio: Full output is reached when tension is at 10 or 4 times the
calibration weight
• Flexible Mounting: 35mm DIN Rail, Panel Mount, or Pole/Pipe Adapter
1