Aqua Medic DC Runner 9.2 Manual de operação - Página 2

Procurar online ou descarregar pdf Manual de operação para Bomba de água Aqua Medic DC Runner 9.2. Aqua Medic DC Runner 9.2 4 páginas.

Aqua Medic DC Runner 9.2 Manual de operação
1. Scope of delivery
DC Runner - adjustable low voltage circulation pump, 24 V DC
DC Runner Controller – fully automatic pump control unit with eight different levels for adjusting
the output.
Electronic Safety Transformer - Input: AC 110 – 240 V / 50/60 Hz, Output: 24 V DC
2. Features and Functionality
The DC Runner are magnetically coupled current pumps and have a fully encapsulated synchronous
motor. All materials are salt-water resistant.
The pumps are operated at 24 V DC safety voltage, with the transformer included. They are controlled
via DC Runner Controller which allows for running a variety of different levels.
The DC Runners are suitable for installation under water and out of water.
3. Technical Data
Type
DC Runner
1.2
Power supply
24 V DC
pump:
Power supply
110-240 V AC
transformer:
/ 50/60 Hz
Pump
up to 1,200
output:
l/h
Max. head:
up to 1.5 m
Power
max. 12 watts
consumption:
Connection
25 mm / ¾"
suction side:
Connection
20 mm
pressure
side:
Protection
IP X8
rating:
Fig. 1: DC Runner 1.2
1. Rubber feet
2. Holding plate
3. Pump motor
4. Rear bearing
5. Impeller rotor
6. Front bearing
6
DC Runner
DC Runner
2.2
3.2
24 V DC
24 V DC
110-240 V
110-240 V
AC / 50/60 Hz
AC / 50/60 Hz
up to 2,000
up to 3,000
l/h
l/h
up to 2.2 m
up to 2.7 m
max. 20 watts
max. 25 watts
25 mm / ¾"
32 mm / 1"
25 mm / ¾"
25 mm / ¾"
IP X8
IP X8
7. Housing's sealing
8. Pump lock
9. Seals for pressure connections
10. Filter basket
11. Sealing plug
DC Runner
DC Runner
5.2
9.2
24 V DC
24 V DC
110-240 V
110-240 V
AC / 50/60 Hz
AC / 50/60 Hz
up to 5,000
up to 9,000
l/h
l/h
up to 3.5 m
up to 4.8 m
max. 50 watts
max. 65 watts
32 mm / 1"
40 mm / 1¼"
32 mm / 1"
40 mm / 1¼"
IP X8
IP X8