Installation
The controller has 3 wires:
•
Power with female JEITA connector
•
RS232 with 3 pin Terminal Strip
•
RS485 with 2 pin Terminal Strip
Maximum distance for RS232 is about 10 meters. Maximum distance for RS485 is about 1200 meters.
Connection Diagram
Power + RS-232 + RS-485
Connecting multiple cameras by RS232
The VISCA protocol supports up to 7 cameras and can be cascaded by connecting RS232-out from
each camera to RS232-in of the following according to the picture: