AVS SCOPE212VIR3 Manual do utilizador

Procurar online ou descarregar pdf Manual do utilizador para Câmara de segurança AVS SCOPE212VIR3. AVS SCOPE212VIR3 2 páginas. 3 mega pixel hd network ir dome camera

3 MEGA PIXEL
HD NETWORK
IR DOME CAMERA
USER'S MANUAL
■ Sony 3Mega Pixel Image Sensor
■ Triple Codec (H.264/MPEG4/MJPEG)
■ Triple Stream
■ Support Onvif
■ Support POE
IR LED : 35 units 850nm Infrared LED, 20,000hrs
Night View Distance : Indoor 35 / Outdoor 25m
Sense-Up (x6)
True Day & Night(ICR)
True 3-Axis Easy Ball type Gimbal Bracket built-in
Built-in Heater & Blower
Weatherproof (IP68)
IP3-003
3. Specification
CAMERA SECTION
IMAGE
Image Sensor
1/2.8" Sony Exmore 3MP Image Sensor
Scan System
Progressive Scan
Total Pixels
2144(H) x1588(V), 3.40 Mega Pixels
E ective Pixels
2048(H) x1536(V), 3.14 Mega Pixels
Function
Day & Night
Auto/Day(Color)/Night(BW)
Privacy Area
On/O (6 Programmable Zone)
WDR
DWDR (1~5Step)
DNR
1~63
Motion Detector
48 Zone (On/O , 1~5Step)
Elec. Shutter
Auto(1/15~1/10000),
Suppress Rolling, Manual
Sense Up
1~6 Step
White Balance
Auto/Indoor/Outdoor/Fluorescent
Ext. Video
VBS1.0Vp-p
Lens
Focal Length
2.8~10 Mega Lens
IR LEDs
IR LEDs
35 units
Night View Distance
25m
Electrical
Power Supply
DC12[V] ±10% / POE
Current
Max 650mA
Environmental Operating Temp.
-10
~ +50
Preservation Temp.
-20
~ +60
Humidity
0% ~ 90%
Mechanical Weight
Approx. 1,050 g
NETWORK SECTION
System
OS
Embedded Linux
Network
Interface
RJ45 100/100 Base-T PoE
Protocol
TCP/IP,UDP/IP,RTP,RTSP,RTCP,NTP,
HTTP,DHCP,FTP,SMTP,DNS,DDNS
Onvif
ver2.0
DDNS
iplinker.net
Simultaneous Access
Max. 10 user
Video
Compress Format
H.264/MPEG4/MJPEG
Resolution
2048×1536/1600×1200/1920×1080/
1280×1024/1280×720/640×480
Frame rate
5fps ~ 15fps @ all resolution
Video Quality
H.264,MPEG4 : Bitrate Control
MJPEG : Quality Level Control
Streaming
Triple Stream (Stream1,2,3)
RTP/RTSP, UnicastRTP, Multicast RTP
Audio
Compress Format
G.711 u-law
Streaming
Two way
Event
Sensor In
1 (Digital Input)
Alarm Out
1 (Digital Outut, Open Collector)
Web
Manager
IE, Firefox, Safari, Opera
Browser
Viewer
IE only (Active-X)
Design and specifications are subject to change without notice.
Components & Dimension
SCREW
L-WRENCH
SUPER
WDR/3D DNR
DOME CAMERA
USER'S MANUAL
70.0
Mounting Template
Surface Mount
Sony 1/3" Color Vertical Double Density CCD
Sony 1/3" SuperHAD II CCD
960H CCD (700TV Lines)
High Resolution 600TV Lines
WDR(Wide Dynamic Range)
High Resolution 700TV Lines(960H)
Eclipse Function
Sens-Up Function(x512)
3D DNR(Digital Noise Reduction)
UTP Interface Optional
RS485 ( PELCO-D) Optional
35pcs IR LED Vandal Dome Camera or
Heater & Blower Option
Non-IR LED Vandal Dome Camera
Flush or Surface Mounting Type
IP67 rate Waterproof Design
True 3-Axis Easy Ball Type Gimbal Bracket built-in
Manual
Mounting Template
SIDE CAP
Dimension
unit :mm
174.7
PF 3/4"
4 . Interface & IP Initization
Power
Audio Out(yellow)
GND (Black)
Audio In(White)
Service Video
LAN Cable
Sense In (Yellow)
GND (Black)
Alarm 12V Out (Red)
Alarm Out (White)
IP Initialization
IP Address
192.168.1.30
Gateway
192.168.1.1
Subnet mask
255.255.255.0
Factory
Default
I D
admin
Password
admin
Web Port
80
RTSP Port
554
* You should change the ID and Password after purchasing.
* You will be responsible for all the damages unless you change the ID and
Password.
1. Names and Functions of Parts
10
Plastic Anchors
11
3/4" Cap (2EA)
12
Surface Mounting Screws
M4 x 30
9
Surface Mount
Surface Mount
8
Fix Screw
7
Flush Mount Base
6
Bracket
Heater & Blower Board
13
(Optional)
5
Gimbal
Assembly Screw(Surface Mount)
14
4
LEDs
M4 X 10 (4EA)
3
Lens
15
Safety Cable
Dome Cover
2
1
Bubble
Assembly Torx Screw
16
M4 X 9(3EA)
5. IP Manager
You can do all the settings about network by IP Manager.
1) Run IP Manager
2) Click Find
3) Choose the cameras you want to change
4) Click Change
2)
3)
4)
5) Click Batch
2)
3)
4)
6) If you want to change many IP addresses, you can enter the starting
IP address and the ending IP address, and enter each increasing step.
7) Click Save
2. Installation
Surface Mount Installation
STEP :
1. Mount the surface mount
plate to a sturdy surface or
wall with the installation
template (mouting screws
1
M4 x 30).
2. Connect the pre-drilled two
screws in the flush mounting
ring through the locking
hole(
) and turn it
counterwise for the
temporary locking system
UNLOCK
LOCK
2
before drilling four screws
(M4 x 10) of flush mount ring.
Please check if the
symbol
in the surface mount ring and
the square hole (
) in the
flush mount ring meet in a line
when it is locked.
3
3. Screw with four screws
(M4 x 10) from flush mount
ring to be mounted with the
surface mount.
4. Adjust the lens focus and zoom
of camera to monitor the objective.
1
Surface Mount Ring (Symbol)
5. Fit three screws(M4 x 9) from dome
Flush Mount Ring Square Hole
cover ring to the flush mount ring
2
and fix it by (3) screws. When you fit
Dome Cover Ring (Symbol)
3
the dome cover ring please fit the
symbols in the line.
6)
7)
8) Con rm if the changing values are correct.
9) Click Change
8)
9)
10) Check the Status