PROBLEM
No response when the
power is turned on
Circuit breaker on
control panel or
building "trips".
Filter change indicator
is ON".
Note: If the unit does not start or malfunctions after carefully following the TROUBLESHOOTING GUIDE, call
Abatement Technologies service department at +1 800-634-9091 (U.S.) or +1 905-871-4720 (Canada) for
assistance.

TROUBLESHOOTING GUIDE

POSSIBLE CAUSE
Power cord unplugged.
Defective power cord.
Tripped circuit breaker.
Tripped ground fault circuit
interrupter or residual current
device.
Thermal overload on the
motorized impeller has tripped.
Overloaded circuit.
Loaded filters.
Excessive restrictions.
If using a carbon pre-filter,
carbon filter has not been
removed from polybag.
Plug power cord firmly into electrical outlet in
Check all connections and condition of cords.
Do not operate with damaged power cord(s).
Reset breaker for building.
Reset 12 amp breaker located on unit.
Reset GFCI on control panel or GFCI/RCD at
Note: Unit must be plugged in when resetting
GFCI on control panel.
Turn unit "OFF", wait 30 minutes and restart
Unplug any additional equipment connected
to the circuit. Reset circuit breaker.
Change in accordance with operating
Reduce bends, length of flex duct, or
eliminate restrictions.
Remove carbon filter from polybag.
12
SOLUTION
wall.
the power source.
unit.
instructions.