reading is 7.00 VDC, although useful operation can be obtained with battery voltages all the way to 6.00 VDC.
During operation, the amount of battery life remaining will be displayed in the battery symbol on the display.
When the battery is correctly installed, you will hear 2 tones followed by 5 faster tones. After the control and
display unit connects with the scale platform, the voltage of the battery pack in the platform will be shown on
the display (See Fig. 7). CPS recommends changing the scale platform batteries when the reading is 4.5 volts,
although useful battery operation will result all the way down to 4.2 VDC; always use a set of 4 AA alkaline
cells. When batteries are correctly installed, the scale platform will product a 7 tone musical tune.
Note : For optimum performance, always replace both the HHLD and the Scale Platform batteries at
the same time. Ensure that you hear the appropriate tone, if not, remove, wait 1 minute and reinstall
battery.
Note : It is recommended that the HHLD and the Scale Platform be turned off prior to removing any
batteries.Removing a battery when the Scale Platform is connected to the Hand Held, may cause the
system to hang-up.Remove batteries from both devices if you feel you must remove a battery during
operation.
Low Battery Indication:
If the system detects a low battery condition, the system will turn itself off in a safe condition. The display will
show the word "CELL" and either "rxxx" or "Lxxx". The "r" indicates the voltage of the scale platform batteries
and "L" the voltage of the control and display unit battery voltage (See Fig. 3 & 7). The display then changes to
"CPS Abrt" after a brief delay and then the system shuts off.
External Interference:
In the unlikely event that the CC240RF has difficulty maintaining connectivity or has numerous instances of
the display freezing, no response to key entries, etc. the most probable cause is interference from other ISM
band devices in the same channel. In that case, press and hold the POWER [
To check that the channel has changed, press and hold the POWER [
The display will show all [4 id / Good] settings and then will show the new channel number and return to the
normal weigh mode.
This product conforms to the applicable parts of FCC Rule 15.
This instrument contains one or more
RF devices with FCC ID: X8BMT240, IC: 8826-MT240.
] key and then press the [LB / KG] key.
9
OPERATION
] key and press the [TARE] key.