5. Fault status: the alarm will deliver beeps every 40
seconds.
Silence Mode
During the unit is alarming, you can push the test button, it
will be paused the unit alarming for approx 10 minutes. The
red LED will flash once every 8 seconds, it indicates the
smoke alarm device is running into the silence mode.The
silence feature is to be used only when a known alarm
condition, such as smoke from cooking activates the
alarm.The smoke alarm device will automatically reset after
approximately 10 minutes, if after this period, particles of
combustion are still present, the alarm will sound again.
CAUTION:
Before using the alarm silence (silence), identify the source
of the smoke and be certain a safe condition exists.
Interlinked smoke detector
Radio-interlinked smoke detectors are interlinked through radio-
frequency signals. If one smoke alarm detects fire, all alarms go
off. In the case of
the battery operated radio-interlinked smoke alarms, no wiring is
required at all.
How to create the interlinked network
Step 1: Press the test/silence button on one of these smoke
alarms 4 times, and the green LED will rapidly flash continuously,
indicating it has entered the transmitting mode (valid time: 60
seconds) .
Step 2: Press the test/silence button on the other smoke alarms
twice, and the green LED will slowly flash continuously,
indicating it has entered the receiving mode.
-----If pairing is successful: The green LED of these alarms will
stop flashing.
-----When it is failure: The green light will continue to flash for
60 seconds, and then the red light will stay on for 2 seconds.
How to disabling the interconnect function
Press the test/silence button on the smoke alarms twice and the
green LED will slowly flash continuously still 60 seconds, then
ignore it and it will automatic despairing.
How to silence the alarms in network when alarm
If the smoke alarm detects fire, the device will goes into
Source/Master smoke alarm sound pattern alarmed, and emits the
alarm signal;