Procurar online ou descarregar pdf Manual de instruções original para Equipamento industrial ABB 2TLA050220R0222. ABB 2TLA050220R0222 14 páginas. Emergency stop

Safety-related characteristic data and Conformity
Conformity
EN ISO 13849-1
EN 62061
Safety data
Mechanical reliability B
10d
PFH
D
Proof test interval (life)
MTTF
d
Certifications
Information with regard to UL 508
2TLC172247M0201, rev. B
2013-04-11
European Machinery Directive 2006/42/EC
EN ISO 12100:2010, EN ISO 13850:2008, EN 60204-1:2006+A1:2009
EN 60947-1:2007+A1:2011, EN 60947-5-1:2004+A1:2009,
EN 60947-5-5:1997+A1:2005
Up to PL e, cat. 4 depending on system architecture
Up to SIL3 depending on system architecture
1 500,000 operations at 100 mA load
<1.0 x 10-7
21 years
214 years (8 cycles per hour/24 hours per day/365 days per year)
TÜV, cULus
Use 12AWG copper conductors only
Electrical Rating: A300 48W5
Type 1 Enclosure
Max. Switching Current / Volt / Amp: 120V 6A (720VA break) PF 0.38,
240V 3A (720VA break) PF 0.38
12
www.abb.com/jokabsafety