If the alarm output and/or LED indicate a fault (RED):
1.
Remove the rear cover, and use the builtin gauge to check the
location of the rotor (see Figure 1). Ensure the label marked "This side
out" is facing away from the motor.
2.
Remove the AV85 from the motor. Clean the housing mounting
surface for the AV85 housing. Ensure the AV85 is directly mounted on
the motor, with no sealant, gasketing, or other materials, and is firmly
bolted in place.
If the alarm output and/or LED indicate a fault (RED)
On a properly mounted AV85 and the rotor is properly located, replace
the AV85 sensor.
An oscilloscope can also be used to verify proper output of the encoder
at the encoder connector itself and at the drive/controller cabinet.
If the outputs show large variations in the signals at steady speed
(jitter or "accordion effect", see figure 5), check rotor position. If the
rotor position is correct, the motor or shaft may be highly magnetized.
Replace any magnetized material nearby with nonmagnetic material
(aluminum, stainless) (especially shafts). For GE CD frame motors and
similar styles, Avtron offers nonmagnetic stub shafts. If variations
persist, consider replacing the encoder with supershielded models,
option 005, or use retrofit shielding kits AVSKxxx yy z, where
xxx=model (ex: 56A), yy=rotor (ex: CB), and z=cover (ex: F).
If the alarm output and/or LED indicate a wiring fault (ORANGE):
Remove all output wires/connections (A,A/,B,B/,Z,Z/). The LED should
turn GREEN. If the LED does not turn GREEN, the encoder is not
receiving enough voltage at +V to properly operate. Correct input
voltage problem at power supply or cabling.
If the LED turns GREEN once all outputs are disconnected, reconnect
each output, one at a time, monitoring for ORANGE LED. For partial/
resistive short circuits, the LED may take a few minutes to turn
ORANGE. To speed the troubleshooting process, if possible, spin the
encoder while replacing individual output connections. This will make
the ORANGE LED condition occur faster. Once the shorted output(s)
are located, correct the shorting condition, and the encoder LED should
remain GREEN.
If the LED is OFF, but power is being applied to the encoder, check
the output voltage level at A, A/,B, B/. If all outputs are ON (≈+V), the
connections to +V and COM are reversed. Swap connections between
+V and COM; the LED should turn GREEN.
NOTE:
Do not use rotors from THIN-LINE I (M56, M56S, M67,
M85, M115) with THIN-LINE III. This will cause incorrect
PPR output, but the Encoder LED will remain green.
Obsolete Spare Parts
Option
Shaft Size
Code
1.1250"/1.1245" x 0.40"
EF
2.1250"/2.1245" x 0.40"
EN
2.3750"/2.3745" x 0.40"
EP
2.8750"/2.8745" x 0.40"
E2
Hardware
Rotor PN
provided
AVTR1-EF 3/8"-16 x 1" + roll pin
AVTR1-EN
10-24 x 0.5" (2)
AVTR1-EP
3/8"-16 x 0.88" (2)
AVTR1-E2
3/8"-16 x 0.88" (2)
AV85
ENCODER REMOVAL
The AV85 stator housing can be removed by loosening and removing
the socket head cap screws.
CAM SCREW AND END-OF-SHAFT ROTOR REMOVAL
Disengage the (2) cam screws or endofshaft mounting screw(s) by
turning them counterclockwise less than 1 full turn. The cam heads
will visibly move away from the shaft. Remove the rotor by hand by
pulling it away from the motor. If the rotor will not move, do NOT use a
gear puller, and do not use a heat gun. Instead, insert two M6 screws,
>25mm length into the Jack Screw Holes shown in Fig 2. Alternately
tighten the screws to push the rotor away from the motor
and remove it.
LARGE BORE SET SCREW ROTER REMOVAL
Disengage the (2) set screws by turning them counterclockwise until
removed from the rotor. Retain the set screws. Remove the rotor by
hand by pulling it away from the motor. If the rotor will not move, do
NOT use a gear puller, and do not use a heat gun. Instead, pry the rotor
away from the motor gently, being careful to only pry against the rotor
metal hub and not the magnetic outer strip.
CONNECTOR SPARE PARTS
OPTION
STYLE
ENCODER SIDE
CODE
Industrial
315233
EPIC on
P,G
Encoder
315229 Terminal
Industrial
EPIC w/
Q
Adapter
Block
315232
Industrial
EPIC on 3'
Z
315229 Terminal
Cable
471819 Bushing
Mini-MS
R, S
315296
Twist Lock
314383
10 pin MS
Y
on cable
PHASE A
PHASE B
VARIATION > ± 15%
FIGURE 5
4
CABLE SIDE PLUG
Base
315937
Hood
315936
Terminal
Conn1-02
401112
Adapter
Surface
315937
Hood
Conn1-02
315936
Terminal
401112
Adapter
Base
316110
Plug
In-Line
315932
Plug
411216
Conn1-01
411217
Cable
Bushings
411218
411219