Removing the Optional 1x2 Flex Bay Bracket

If your system has the optional 1x2 flex bay, use the following procedure to remove the 1x2 flex bay
bracket:
1 With the system cover removed, push the spring latch on top of the peripheral bay to the right to
release the flex bay bracket (see Figure 1-8 for latch location) and push on the back of the flex bay
bracket to extend the bracket partially out of the chassis.
2 Note the order of SAS cable connections on the flex bay backplane and disconnect the SAS cables.
3 Disconnect the power cable from the flex bay backplane.
4 Remove the 1x2 flex bay bracket from the chassis bay.

Removing the Control Panel Assembly

NOTE:
The control panel assembly's display module and the I/O board are the same for both the tower and rack
systems. When converting your tower system to a rack system, you must remove the display module and the I/O
board of the control panel assembly and reinstall the assembly in the rack orientation.
1 Disconnect the display module cable from the control panel board. See Figure 1-4.
Carefully pull up on the locking ring on top of the connector until the cable loosens.
a
Remove the cable.
b
2 Using the T10 Torx driver, remove the three M3 Torx panhead screws that secure the control panel
board to the system chassis and remove the board. See Figure 1-4.
3 Disconnect the control panel cable from the back of the control panel. See Figure 1-4.
NOTICE:
Do not pull on the cable to unseat the connector. Doing so can damage the cable.
Squeeze the metal tabs on the ends of the cable connector.
a
Gently work the connector out of the socket.
b
4 Remove the display module:
Insert the end of a paper clip into the hole on the right side of the display module and gently
a
pry the label off. Discard the label.
Using a T10 Torx driver, remove the two M3 x 12 T10 Torx panhead screws that secure the
b
panel to the system front panel. See Figure 1-4.
Remove the display module from the front panel cutout.
c
Tower-to-Rack Conversion Guide
13