Dell PowerEdge C2100 Instruções de utilização - Página 20

Procurar online ou descarregar pdf Instruções de utilização para Servidor Dell PowerEdge C2100. Dell PowerEdge C2100 32 páginas. Poweredge series
Também para Dell PowerEdge C2100: Manual da carteira (27 páginas)

Table 1-21. Platform Event Filters List
Action
Reboot System
Power Cycle System
Power Off System
Generate Alert
To set up the actions and alerts, perform the following steps:
1 Click the Event name in the Platform Event Filters List.
The Set Platform Events window for that event opens.
2 Set the Shutdown Action and Alert Setting for the event.
3 Repeat steps 1 and 2 for each event.
4 To enable the settings, see the platform event filters configuration procedure.

Serial Over LAN Configuration

To configure the Serial Over LAN Configuration Advanced Settings, select values for each
attribute in Table 1-22, and click Apply Changes.
To enable and configure the Serial Over LAN Configuration, click Return to Serial Over LAN
Configuration Page at the bottom of the window.
Table 1-22. Serial Over LAN configuration
Item
Enable Serial Over LAN
Baud rate
Privilege level
20
Using the Baseboard Management Controller
Description
When an event occurs, the system restarts (a warm boot).
When an event occurs, the system shuts down, powers off, and
restarts (a cold boot).
When an event occurs, the system shuts down and powers off.
An alert or platform event trap is sent when the event occurs. The
email server and address to which the alert is sent, can be set in the
Configuration Email Alert Settings window.
Event trap destinations can be set in the Configuration Trap
Settings window.
Description
Checked indicates enabled; Unchecked indicates disabled
Select a IPMI data speed of 9600 bps, 19.2 kbps, 38.4 kbps, 57.6 kbps,
or 115.2 kbps
Select the IPMI Serial Over LAN minimum user privilege:
Administrator, Operator, or User.