Troubleshooting

The basic service guide as follows should cover most performance
issues. If you continue to experience issues after referring to this
list, please contact DH Lifelabs customer support.
Symptom
Probable Cause/Solution
If the device fails to power on, the issue may be the result
of one of the following causes. In some cases, the device
Air purification is
will require service by the manufacturer or a professionally
inoperable.
licensed electrician.
1. blown fuse: replace the fuse
2. PCB board malfunction: replace PCB board
If the device powers on but failes to operate, the issue
may be the result of one of the following causes, and will
Air purification
require service by the manufacturer or a professionally
indicator is on but
licensed electrician.
inoperable.
1. fan/ motor malfunction: check if the indicator flashing
in red, if so, replace the fan/ motor
2. PCB board malfunction: replace PCB board
1. HEPA filter may be dirty or obstructed. Replace filter.
Reduced airflow.
2. Air inlet grill and air outlet grill may be dirty or
obstructed. Clean the grill.
The first time you use the device, you might perceive
Air coming in
a plastic or paint smell. This is normal, but it should
disinfection mode
disappear quickly. If the smell persists or if you sense
has a bad odor.
a burning smell, please turn off the device and
contact customer support.
Air quality does not
Windows or doors are open. Constant introduction
improve as the
of dirty air from outside the room can reduce the
disinfection mode
effectiveness of the disinfection. Close all exterior doors
operates.
and windows.
The device is
Check and ensure that there are no obstacles near the
functioning with very
device.
loud noise.
Check what color is flashing.
Flashing red: Motor error. Replace motor, requiring service
The indicator light
by the manufacturer or a professionally licensed electrician.
flashing.
Flashing blue: Filter change cycle timer expired. Replace
filter and reset timer.
13
Troubleshooting (Cont.)
Symptom
Probable Cause/Solution
The issue may be the result of one of the following
causes, and will require service by the manufacturer or a
Lighting function is
professionally licensed electrician.
off or slightly bright.
1. The CCT switch is not in good contact: Re-flip the CCT
(only available for
switch a few times, if the fault persists, replace the PCB
Sciaire Pro Ceiling
board.
Light device)
2. The dimmer knob is turn to the minimum position:
Adjust the dimmer from the minimum position to other
positions.

Product Warranty

This 3 year limited warranty applies to repair or replacement of product found to be
defective in material or workmanship. This warranty does not apply to damage resulting
from commercial, abusive, unreasonable use or supplemental damage. Defects that are
the result of normal wear and tear will not be considered manufacturing defects under
this warranty.
DH Lifelabs IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF
ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURA-
TION OF THIS WARRANTY.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential
damages or limitations on how long an implied warranty lasts, so the above limitations
or exclusions may not apply to you. This warranty gives you specific legal rights, and
you also may have other rights which vary from jurisdiction to jurisdiction. This warranty
applies only to the original purchaser of this product from the original date of purchase
At its option, DH Lifelabs will repair or replace this product if it is found to be defective in
material or workmanship. This warranty does not cover damage resulting from any unau-
thorized attempts to repair or from any use not in accordance with the instruction manu-
al. This warranty does not cover the filter except for material or workmanship defects.
14