Também para Dell PowerEdge M520: Atualização da informação (38 páginas), Notas de lançamento (27 páginas), Manual (25 páginas), Manual do utilizador (23 páginas), Manual de informações importantes (35 páginas), Manual de atualização (32 páginas), Manual de atualização (28 páginas), Manual do utilizador (26 páginas), Manual do utilizador (22 páginas), Manual de iniciação (12 páginas), Manual técnico (45 páginas), Manual da carteira (27 páginas), Manual de iniciação (14 páginas), Manual de iniciação (12 páginas)

Dell PowerEdge M520 Manual técnico
Feature
Fresh Air
Rack infrastructure
Find additional information at

Power supply units

The M1000e chassis enclosure provides power and cooling for the M520 blade server. For
information on the M1000e power supply units, see the
Dell.com/PowerEdge.

Thermal and acoustics

Optimized thermal management keeps fan speeds in the PowerEdge M520 as low as possible,
contributing to quiet operation and ensuring proper component cooling.
Thermal design
The thermal design of the PowerEdge M520 reflects the following:
Comprehensive thermal management: The PowerEdge M520 dynamically controls system
cooling fan speed, based on responses from critical sensors that monitor the temperature of
several components, including:
Processors
DIMMs
System inlet ambient
Mezzanine card
Thermal control also detects and responds to hardware configuration. Thermal management
adjusts cooling according to what the system really needs, and draws lower fan power draw and
generates lower acoustical noise levels than those without such controls.
PowerEdge M520 Technical Guide
27
Description
complete power management solution comprised of Intel Node Manager
accessed through Dell iDRAC7 Enterprise and OpenManage Power Center
that allows policy-based management of power and thermals at the
individual server, rack and data center level.
Hot spare reduces power consumption of redundant power supplies.
Thermal control of fan speed optimizes the thermal settings for your
environment to reduce fan consumption and lower system power
consumption.
Idle power enables Dell servers to run as efficiently when idle as when at full
workload.
With the thermal design and reliability of Dell products, you can have the
capability to operate at excursion-based temperatures. This solution is
comprised of servers, networking, storage, and infrastructure that run
beyond the industry standard of 35°C (95°F) without impacting your
availability model. Find additional information at Dell.com/FreshAir.
Dell offers some of the industry's highest-efficiency power infrastructure
solutions, including:
Power distribution units
Uninterruptible power supplies
Energy Smart containment rack enclosures
Find additional information at
power-and-cooling-technologies-components-rack-infrastructure.aspx.
Dell.com/PowerAndCooling
http://content.dell.com/us/en/enterprise/
and Power.com/PowerCenter.
PowerEdge M1000e Technical Guide