Dell Equallogic PS6510e Manual do hardware - Página 46

Procurar online ou descarregar pdf Manual do hardware para Armazenamento Dell Equallogic PS6510e. Dell Equallogic PS6510e 50 páginas. Equallogic
Também para Dell Equallogic PS6510e: Visão geral (7 páginas), Características (2 páginas), Manual de referência rápida (2 páginas)

Dell Equallogic PS6510e Manual do hardware
Problem
The storage array firmware upgrade
process using Telnet, exits without
allowing you to enter y to the
following message:
Do you want to proceed
(y/n)[n]:
While running the Cluster Validation
Wizard, the Validate IP Configuration
test detects that two iSCSI NICs are
on the same subnet and a warning is
displayed.
46
Probable Cause
The Telnet program sends an extra
line after you press <Enter>
The two iSCSI NICs are configured in
the same subnet by design.
Corrective Action
User serial connection for the array
firmware upgrade.
To clear the extra linefeed in
Windows Telnet:
1. Enter ^](control, right bracket).
2. In the Microsoft Telnet prompt,
type unset crlf.
3. Press <Enter> to return to
Telnet.
No action required.