Dell PowerVault 50F Manual do utilizador - Página 29

Procurar online ou descarregar pdf Manual do utilizador para Armazenamento Dell PowerVault 50F. Dell PowerVault 50F 42 páginas. Dell powervault 56f switches rack installation guide
Também para Dell PowerVault 50F: Manual de ligação (38 páginas), Manual de instalação (8 páginas), Manual de instalação do bastidor (28 páginas)

Dell PowerVault 50F Manual do utilizador
support.dell.com
Port Status field
Port Type field
PortStats tab
4-Byte Word
Transmitted field
4-Byte Word
Received field
Frames Transmit-
ted field
Frames Received
field
C2 Frames
Received field
C3 Frames
Received field
No_Module — No GBIC module in this port
No_Light — The module is not receiving light
No_Sync — The module is receiving light but is out
of sync
In_Sync — The module is receiving light and is in
sync
Laser_Flt — The module is signaling a laser fault
(defective GBIC)
Port_Flt — The port is marked faulty (defective
GBIC, cable, or device)
Diag_Flt — The port failed diagnostics
Online — The port is up and running
Lock_Ref — The port is locking to the reference
signal
E-Port — Switch link port
G-Port — Generic port
U-Port — Universal port
F-Port — Fabric port
FL-Port — Fabric loop port
L-Port — Loop port
Number of four-byte words transmitted
Number of four-byte words received
Number of frames transmitted
Number of frames received
Number of class 2 frames received
Number of class 3 frames received
Using the Dell PowerVault Switch Manager
2-19