Dell PowerVault MD3800f series Manual do Proprietário - Página 19
Procurar online ou descarregar pdf Manual do Proprietário para Armazenamento Dell PowerVault MD3800f series. Dell PowerVault MD3800f series 47 páginas. Storage arrays
Também para Dell PowerVault MD3800f series: Manual de implantação (34 páginas), Manual de iniciação (8 páginas)
Installing the Front Bezel
1.
Hook the right end of the bezel onto the chassis.
2.
Fit the free end of the bezel onto the system.
3.
Secure the bezel with the keylock.
Physical Drives
SAFETY Models AMT E03J and E04J
Models AMT, E03J, and E04J are intended for installation only in restricted access locations as defined in
cl 1.2.7.3 of IEC 60950-1:2005.
Depending on your configuration, your array either supports up to twenty-four 2.5-inch SAS physical
drives or up to twelve 3.5-inch SAS physical drives in internal drive bays. Physical drives are connected to
a backplane through physical-drive carriers and can be configured as hot-swappable.
Removing a 2.5 Inch Physical-Drive Blank
CAUTION: To maintain proper system cooling, all empty physical-drive slots must have physical-
drive blanks installed.
1.
If installed, remove the front bezel.
2.
Press the release button and slide the physical-drive blank out until it is free of the physical-drive slot.
Figure 11. Removing and Installing a 2.5 Inch Physical-Drive Blank (MD3820f only)
1.
physical-drive blank
Installing a 2.5 Inch Physical-Drive Blank
1.
If installed, remove the front bezel.
2.
Insert the physical-drive blank into the physical-drive slot until the release button clicks into place.
3.
If applicable, install the front bezel.
2.
release button
19