Ensy AHU Series Procedimento de arranque - Página 7
Procurar online ou descarregar pdf Procedimento de arranque para Ventilador Ensy AHU Series. Ensy AHU Series 8 páginas.
393803‐2 Startup procedure for EnSy AHU units
8. Checking settings for the fans when activating cooker hood / kitchen
ventilator.
To get balanced ventilation when you activate the cooker hood or kitchen ventilator you should
adjust the settings.
Change values with control buttons 2 (‐) or 3 (+).
After setting press control button 1 (Return) three times to get back to start menu..
Here the values for Supply air and Extract air should be set to same values as for MAX in menu
4.5.1.3. Fan control in the user manual that follows this unit.
If an active kitchen ventilator is used.
If an active kitchen ventilator is used, then Extract air should be set to 50% or less to compensate for
the air that is extracted via kitchen ventilator.
We reserve the right to change technical data without notice http://www.ensy.no
REV:0_08.09.2016. KJK
If a cooker hood is used.
Press control button 4 once to get into 4. Preferences.
Press control button 3 three times to get to Setup menu.
Press (Enter) control button 4 to get into 4.5 PIN code menu.
Press control button 3 (+) once and you will have 1000 in
display.
Press control button 4 (enter) four times and OK will show up in
display.
Press control button 3 (OK) to get into 4.5.1 Setup.
Press control button 3 four times to get to Cookerhood.
Press control button 4 (enter) to get into 4.5.1.5 Cookerhood
menu.
Set to 100% from factory.
Move between Supply air and Extract air with control button 4.
Page 7