Step
Task
Verify that the power source complies with the system input power
1
requirements.
Energize the remote power source or outlet.
2
On the C7004/C150, toggle the switch on the AC power supplies to the
3
ON (right) position.
On the C7008/C300, toggle the switch on the AC power supplies to the
ON (top) position.
The power supply LEDs shows green. If these LEDs are not lit green:
4
• Check that the unit is properly installed.
• Verify the power source.
• If the power supply cannot be verified, power off all modules and
replace the unit.
The fan tray LED shows green (online). You can hear the air flowing
5
through the chassis. If the fans are not operating properly or air is not
flowing through the chassis:
• Power off all power supplies.
• Verify that the fan tray is properly installed.
• If the fan tray LED remains unlit, power down the unit, and replace the
fan tray.
After you supply power to the system, the following occurs:
•
The fan tray is operating.
•
The green (online) fan tray, RPM, and line card LEDs are lit and remain lit as
long as the system is receiving power and is operational.
When you supply power to the chassis, the system performs a series of power-on
self tests. RPM and line card LEDs blink as the diagnostic programs run. You do
not have to do anything while the tests run. Observe the process on your console
monitor. When the boot process completes, the card LEDs remain online (green)
and the console monitor displays the command line interface (CLI) prompt.