Dell EMC PowerSwitch S5148F-ON Manual de configuração
This section lists the S5148F-ON switch specifications.
CAUTION:
Operate the product at an ambient temperature not higher than 0°C to 45°C (32°F to 113°F).
CAUTION:
Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced.
Replace only with same or equivalent type of battery. Dispose of the batteries according to the manufacturer's
instructions.
NOTE:
For RoHS information, see
Topics:

Chassis physical design

Chassis physical design
Table 1. Chassis physical design
Parameter
Height
Width
Depth
Chassis weight with factory-installed components
Rack clearance required
Table 2. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
18
Specifications
Restricted Material
Compliance.
Specifications
1.72 inches (44 mm)
17.1 inches (434 mm)
18.1 inches (460 mm)
PSU/fan tray handle: 1.57 inches (40 mm)
19 lbs (2* PSUs)
8.62 kg (2* PSUs)
Front: 5 inches (12.7 cm)
Back: 5 inches (12.7 cm)
Specifications
0°C to 45°C (32°F to 113°F) continuously
-5°C to 45°C (23°F to 113°F) short term
Short term is </= 1% of operational hours per year.
5% to 85% (RH), non-condensing, continuously
5% to 90% (RH), non-condensing, short term
Short term is </= 1% of operational hours per year.
-40°C to 70°C (-40°F to 158°F )
5% to 90%, non-condensing
Specifications
NOTE:
Reduce maximum temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters (3,117 feet).