Dell S4148FE Manual de instalação - Página 36

Procurar online ou descarregar pdf Manual de instalação para Interruptor Dell S4148FE. Dell S4148FE 48 páginas.

Dell S4148FE Manual de instalação

Fan LEDs

Solid green—fan function is normal.
Flashing yellow (amber)—there is a fan fault.
Off—fan is off.

Fan module installation

The fan modules in the S4100–ON Series (S4128F-ON, S4148F-ON, and S4148FE-ON) switch are field replaceable.
When looking at your switch, Slot 1 is on the left side of the switch and Slot 4 is on the right side of the switch.
CAUTION:
DO NOT mix airflow directions. All fans must use the same airflow direction—reverse or normal. If you mix the airflow
direction, to avoid overheating the switch, correct the mixed airflow.
1
Take the fan module out of the shipping box.
2
Slide the module into the bay.
Figure 21. S4100–ON Series fan modules installation
1
Fan unit

Fan module replacement

To request a hardware replacement, see
CAUTION:
Complete the following steps within one minute or the switch temperature could rise above safe thresholds and the
switch could shut down:
1
Slide the fan module out of the bay.
2
Slide the replacement module into the bay.
36
Fans
Dell EMC
support.